Installation Clearances
It is extremely important that you respect required installation distances and that you
respect local installation regulations. This is for your safety! The manufacturer is not
responsible for the product, if it is not installed following these recommendations. These
clearances may only be reduced by means approved by the regulatory authority.
A combustible surface is anything that can bum (i.e. sheet rock, wall paper, wood, fabrics
etc.) These surfaces are not limited to those that are visible and also include materials that
are behind non-combustible materials. If you are not sure of the combustible nature of a
material, consult your local fire officials.
I- ,
A
n'
Connector
to backwall
B - Chimney Connector to
sidewall
C - Chimney Connector to
comerwall
o -
Unit to backwall
E - Unit to sidewall
F - Unit to comerwall
Single wall
connector pipe
16.5" (419 mm)
22" (559 mm)
20" (508 mm)
14" (356 mm)
14" (356 mm)
11.5" (292 mm)
Double wall
connector pipe
c--lO.5" (267 mm)
-
18" (457 mm)
15" (381 mm)
.
--,-------­
8" (203 mm)
10" (254 mm)
6.5" (165 mm)