This Fire is classified as a Cooker, therefore not listed on clean air wood fire websites.
BUILDING CONSENTS (PERMITS)
It is the house owners responsibility to have the correct permit lodged and accepted by
the local building authority. Your Installer may offer to assist with this and in some cases
undertake the complete application, lodgement, payment, etc. on your behalf (a fee
maybe incurred).
INSTALLATION
All solid fuel heating appliances sold by Broadys NZ Ltd must be installed to the require-
ments of the Standard AS/NZS 2918:2001 and the product instructions supplied by the
manufacturer. This includes the "FINISHING" of your installation e.g. the correct vent-
ing, hearth sizing, and fascia and/or mantle surrounds.
Broady's NZ Limited do not undertake installation and/or site work associated with the
installation of the products we sell, nor warrant their installation. We recommend that the
installation of all solid fuel heating appliances be carried out by a Qualified Registered
Installer with the NZ Home Heating Association, of which Broady's are also a member.
We can provide a list of these installers, or if preferred visit their website for a full and
current list at www.nzhha.co.nz/membership.asp. By listing these Installers, it is not
implied nor inferred that Broady's recommend them or their work. As the contract for in-
stallation is between you and the chosen Installer – payment is due directly to them, nor-
mally on the completion of the installation. Any possible issues regarding your installa-
tion are to be addressed to the Installer. KEEP THEIR NAME ON FILE.
ELECTRICAL / PLUMBING
If any electrical/plumbing work is required, it must be carried out by a licensed Electri-
cian/Plumber. All electrical work must be carried out to AS/NZS3000 or AS/NZS3100 re-
quirements, plumbing work carried out to appropriate requirements of AS3500.4.1 or
NZS4603, and both electrical and plumbing to local regulatory authority.
•SAFETY WARNING
•Only use dry, well seasoned firewood. Never use driftwood or treated timber
•DO NOT use flammable liquids or aerosols to start or re kindle the fire
•DO NOT OVERFIRE – only use the high heat setting when lighting the fire and reloading.
Once fire is alight reduce air slide control to lower setting. Over firing may result in the
warranty becoming void.
•Replace damaged and worn out consumables like baffles, liners, air tubes, rope seals
etc with genuine replacements to ensure the correct and safe operation of the fireplace.
•If hot water boosters or boilers are fitted the appliance must be connected to an open
vented low pressure hot water system.
•Make sure the minimum safety heater-to-wall clearance distances are maintained be-
tween the heater and any heat sensitive materials (furniture,drapes,blinds etc)
•Solid Fuel heaters with glass doors are not to be used as an open fire.
PDF created with pdfFactory trial version

INSTALLATION INSTRUCTIONS

INTRODUCTION
www.pdffactory.com
April 2011

Advertisement

loading

Summary of Contents for Nectre Fireplaces Baker's Oven

  • Page 1: Installation Instructions

    April 2011 INSTALLATION INSTRUCTIONS INTRODUCTION This Fire is classified as a Cooker, therefore not listed on clean air wood fire websites. • BUILDING CONSENTS (PERMITS) • It is the house owners responsibility to have the correct permit lodged and accepted by the local building authority.
  • Page 2 WATER CONNECTIONS • Viewed from rear • Domestic hot water only Warning - Must be installed to an open vented hot water system • Always check pipe measurements on site • All measurements in mm Clearances from Combustibles Left 350mm Dimensions Right 350mm...
  • Page 3 MINIMUM WALL CLEARANCES & FLOOR PROTECTION REQUIREMENTS 1350 Seismic restraint tabs 1350 min. floor protection • shown by All measurements in mm dotted line • Refer to detailed page on reducing wall clearances These measurements are achieved with the fitting of a ½ round stainless steel flue reflector. The fitting of a splash back does not alter these measurements.
  • Page 4 Tested Freestanding 150mm Flue System Installed to AS/NZS2918:2001 3000mm ADD Cowl Casing Cover Min 600mm above ridge if within 3000mm. Or if beyond 3000mm a min 1000 above roof 600mm Extension Inner liner must rise min 200mm above Weather tight roof cladding Flashing E2 1200 Combination Liner...