Chimney
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR
SYSTEM.
This room heater must be connected to a 6" factory built UL 103 HT chimney (ULe
S629, in Canada) or a code-approved masonry chimney with a flue liner.
Factory Built Chimney
When a metal prefabricated chimney is used, the manufacturer's installation instructions
must be followed. You must also purchase (from the same manufacturer) and install the
ceiling support package or wall pass-through and "T" section package, firestops (where
needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to
the structure as recommended by the manufacturer. The chimney must be the required
height above the roof or other obstructions for safety and proper draft operation. See page
8 for chimney termination requirements.
'~efer toClearal1te~
to CcmbuslibjCS
FIGURE 9