Nectre Fireplaces Big Bakers Oven Installation Instructions Manual

Nectre Fireplaces Big Bakers Oven Installation Instructions Manual

Hide thumbs Also See for Big Bakers Oven:

Advertisement

Quick Links

INSTALLATION &
OPERATING
INSTRUCTION
MANUALS FOR
BIG BAKERS OVEN
FOR NEW
ZEALAND AND
AUSTRALIA
th
Date: 30
Aug 2020
PART ID – 570226-NZ-AUS V2.0

Advertisement

Table of Contents
loading

Summary of Contents for Nectre Fireplaces Big Bakers Oven

  • Page 1 INSTALLATION & OPERATING INSTRUCTION MANUALS FOR BIG BAKERS OVEN FOR NEW ZEALAND AND AUSTRALIA Date: 30 Aug 2020 PART ID – 570226-NZ-AUS V2.0...
  • Page 3 Nectre Big Bakers Oven Installation Instructions Keep these instructions for future reference *Glen Dimplex New Zealand Ltd reserves the right to change specifications, the content of this manual or the design of its product without prior notice. Date: 30 Aug 2020...
  • Page 4: Table Of Contents

    CONTENTS 1. INSTALLATION INSTALLATION ..............1 THE INSTALLATION INSTRUCTIONS IN THIS MANUAL 1.1. IMPORTANT INFORMATION ........1 APPLY TO THE NECTRE BIG BAKERS OVEN. 1.2. INSTALLING THE HEATER ......... 2 1.2.1. Positioning the Heater ........2 1.1. IMPORTANT INFORMATION 1.2.2.
  • Page 5: Installing The Heater

    1.2.3. Corner Installation 1.2. INSTALLING THE HEATER 1.2.1. Positioning the Heater Dimensions given in the image below represent the minimum clearance (in millimeters) to combustible materials. Corner clearance = 275mm Review the necessary clearances specified in this section before considering where to position the heater. Also, check the practicability of installing the flue system in relation to any obstructing roof beams before positioning the heater.
  • Page 6: Reducing Clearances To Combustibles

    INSTALLING THE FLUE If it is necessary to install a heater closer to a combustible The Nectre Big Bakers Oven must be installed with a standard 4.2M long Masport flue system with a dropbox or flue system surface than the stated requirements in this installation...
  • Page 7: Installing Fire Bricks

    INSTALLING FIRE BRICKS A stainless steel rod with a thread at one end and black knob on The Nectre Big Bakers Oven comes with 4 bricks (230 x 115 x the other will have been supplied in the heater. 38mm) held by a 495mm long brick retainer and 2 triangular 1) Pass the threaded end of the rod through the hole near bricks (50 x 70 x 250mm) for the front.
  • Page 8: Technical Drawings

    1.11. TECHNICAL DRAWINGS Front view Wetback Details Top view Flue Spigot Side view...
  • Page 9 Guidelines for low-pressure hot water systems header tank (open vented) Guidelines for low-pressure hot water systems low level (open vented)
  • Page 11 Big Bakers Oven - Technical Specifications Nectre Big Bakers Oven model have been tested & complies to New Zealand National Environmental Safety Test Standard - AS/NZS 2918:2001 Overall Dimensions 690mm Wide x 573 mm Deep x 828mm High Weight 220 kg Big Bakers Oven is a cooking appliance.
  • Page 13 Nectre Big Bakers Oven Operating Instructions Keep these instructions for future reference *Glen Dimplex New Zealand Ltd, reserves the right to change specifications, the content of this manual, or the design of its product without prior notice. Date: 30 Aug 2020...
  • Page 14 CONTENTS 1. OPERATING OPERATING ............... 1 THE OPERATING INSTRUCTIONS IN THIS MANUAL APPLY 1.1. IMPORTANT INFORMATION ........1 TO THE NECTRE BIG BAKERS OVEN. 1.2. GENERAL OPERATION ..........2 1.3. USING THE APPLIANCE FOR THE FIRST TIME ... 2 1.1.
  • Page 15: General Operation

    Do not touch the paintwork while it is curing; otherwise,  The Nectre Big Bakers Oven has two air controls and a bypass it can leave a permanent mark on the appliance. damper for controlling the fire.
  • Page 16: Running The Appliance

    1.6. RUNNING THE APPLIANCE 1.7. OPERATING THE OVEN High Heat Output When using the oven, ensure the bypass damper is in the closed position, and the bottom air slide in the oven door is closed. This setting generates maximum heat output and high oven To maintain constant oven temperature, have the fire temperatures.
  • Page 17: Ash Removal

    Draught is caused by the rising hot air in the flue when the fire 1) Remove the baffle plate (refer to ‘Replacing the Baffle has been lit. Plate’ under Maintenance & Servicing). 2) Hold a small mirror on an angle below the flue, with a The position, height, and size of the flue can affect the torch shining towards it, and look for black creosote performance of the flue draught.
  • Page 18: Maintenance And Servicing

    2.3. REPLACING THE BAFFLE PLATE 2. MAINTENANCE AND SERVICING The baffle plate helps to retain the heat in the firebox by lengthening the path of the flame before it goes up the flue. 2.1. REPLACING THE FIRE BRICKS Over time, the baffle plate will begin to sag a little due to the excessive heat.
  • Page 19: Replacing Door Glass

    2.6. REPLACING DOOR GLASS 2.8. REPLACEMENT SPARE PARTS LIST This task may be easier with the door removed from the Firebricks appliance and laid horizontally on a work-bench. 4 Rectangular @ 230mm x 115mm x 38mm 2 Triangular @ 50mm x 70mm x 250mm To replace the door glass: Brick Retainer 1) Remove the four screws securing the glass retainers to...
  • Page 21 GLEN DIMPLEX WARRANTY REGISTRATION BIG BAKER’S OVEN Thank you for purchasing a Nectre appliance. We ask you to complete the following information and return to the Glen Dimplex Warranty Registration Department on the following address: New Zealand P O Box 58473, Botany, Manukau 2163, Auckland Australia Unit 1, 21 Lionel Road, Mount Waverley, Victoria 3149 Mr / Mrs / Miss / Ms Name: _______________________________________________...
  • Page 23 WARRANTY FOR BIG BAKER’S OVEN This warranty is provided in New Zealand by Glen Dimplex New Zealand Ltd and in Australia by Glen Dimplex Australia Pty Ltd. (together referred as “Glen Dimplex”) This warranty is provided to the first domestic purchaser of a Nectre N65 Low Emission Burner. It applies from the date of purchase from or through an authorized Nectre Fire Distributor in relation to each product or component for the period below.
  • Page 24 What is not covered?  Wear and tear, including wear and tear through normal use on Multi-fuel fire grates and cast- iron firebox liners.  Labor costs relating exclusively to components not manufactured by Glen Dimplex.  Damage caused by incorrect use or the burning of treated or painted wood, driftwood or other fuels which are not recommended;...

Table of Contents