Installation

IMPORTANT – The installation of the Baker's Oven must comply with current local, national,
and/or European regulations applicable to wood burning appliances.
Clearances
The clearances from the appliance to combustible materials must not be less than the
following:-
Rear
250 mm
Side
450 mm
If the appliance is placed in the corner of a room, the minimum clearance from the corner
edge of the appliance to the nearest combustible surface is 250mm.
If the walls adjacent to the appliance are a non-combustible material and minimum 75mm
thick, then the minimum clearance is 25mm.
Never store any flammable materials near the stove.
Hearth Requirements
The hearth on which the Baker's Oven is to be placed should be constructed of non-
combustible material in accordance with Building Regulations Approved Document J (Section
2 – Hearths).
The hearth should extend a minimum 300mm in front of the Baker's Oven.