WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918
AND tHE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS
CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE
FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR CERAMIC TILES, MAY RENDER THE
INSTALLATION UNSAFE.
WHERE A WATER JACKET IS FITTED
WARNING: DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM.
INSTAll IN ACCORDANCE WITH AS 3500.4.1. OR NZS 4603 AND THE APPROPRIATE REQUIREMENTS OF THE
RELEVANT BUILDING CODE OR CODES.
The Nectre Bakers Oven must be installed with a standard ASA 2918:2001 Flue Kit with a 900mm long 180
0
circumference flue mouhted shield
THE FLUE KIT MUST BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS
CONSTRUCTING THE FLUE -
A free standing stove should have a flue kit made of stainless steel or vitre­
ous enamelled steel and it shall extend not less than 4.6m above the top of the floor protector and meets the require­
ments of AS2918/2001 Section 4. The length will depend on ceiling height and roof design but the top of the flue pipe
must be a minimum of 600mm above the ridge if the flue penetrates the roof within 3m of the ridge. Or to be of sufficient
height to be 3m from the roof line horizontally, but a minimum height of 1m.
If the draft is insufficient or periodic down drafting occurs and the stove smokes or only burns slowly, extending the flue or
fitting a specialist cowl will usually cure it.
In the roof cavity and above the roof it is essential that the flue has an outer casing with a reasonable air space (at least
25mm)
between inner and outer pipes. This double flue is important to prevent condensation on the upper cooler parts of
the flue as well as being a safety feature. Where the flue penetrates the ceiling and roof, it must comply with AS2918/
2001. If the stove is fitted into an existing chimney ensure that it is sealed at the base of the chimney with a register plate
and fit the flue pipe up through the plate and continue flue until it terminates outside' the chimney in accordance with
AS2918:2001 4.9.1
D
PECAN ENGINEERING PTY LTD
13 ACORN ROAD
DRY CREEK
SOUTH AUSTRALIA 5094