Menu Options; Print Results (With Optional Printer); View Results; Qc Mode - Midtronics Micro400XL Instruction Manual

Advanced battery & electrical system analyzers, for testing 12-volt automotive batteries, microxl series
Table of Contents

Advertisement

Available languages

Available languages

GB

MENU OPTIONS

To select the following options, which are also available in QC (Quality
Control) mode, press and hold the MENU button.
The Menu options will be displayed three at a time. Use the UP/DOWN
ARROW buttons to scroll through the options and press ENTER to
select.
1. Print Results
(with optional printer)
The results include Battery Test Result and Test Code (if available). For
the Micro500XL the results also include the Starter Test Result and
Charging System Test Result. This option is also available in QC Mode.
In QC Mode, the analyzer will send the complete data set in the QC
memory.
See the section "Printer Setup and Troubleshooting" for more informa-
tion.

2. View Results

The results available above are displayed on-screen. Press the UP
ARROW button to scroll though the results and return to the Menu
screen.
In QC Mode you can view the complete data set in the QC memory.
Press the UP ARROW button to scroll from test to test. Press ENTER
to view the limits set for that test. Press ENTER again to return to the test
result.

3. QC Mode

Select QC Mode to set up the analyzer to act as a quality control device,
which will enable you to test up to 100 batteries in succession without
resetting test parameters. (You can change parameters at any time
during QC testing; the results will be displayed or printed along with the
new parameters.)
1. On/Off: If you turn on QC Mode, it will stay on until you turn it off.
The analyzer will go into Sleep Mode to save the 9-volt battery
power after 30 continuous seconds of voltage loss at the clamps.
When voltage is restored, the analyzer will continue saving data in
QC Mode to the next memory location.
2. Clear Memory, Yes/No: The analyzer's memory holds up to 100 test
results in QC memory. Select YES to clear test results from memory
or NO to continue storing results. When the memory is full, the
analyzer will display the following warning before it starts to over-
write earlier test results:
MEMORY IS FULL/PRESS ↵ ↵ ↵ ↵ ↵ TO OVERWRITE NO. 1
If you want to export or print the stored results before clearing the
memory, press MENU to exit.
3. Select Input/Test By: Select a rating system to TEST BY: CCA, CA,
MCA, and DIN.
E
NGLISH
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro500xl

Table of Contents