F. Set Header
You can create a header for your printed test results showing your
store name, address, and phone number. Use the ARROW buttons
to scroll to the desired character and press the ENTER button to
select and move to the next space. Continue until you have entered
all of the information. The INFO button will move the cursor back one
space. Exit by entering the last available character or by pressing
the MENU button to return to the Menu screen.
G. Test Counter
The analyzer automatically counts the number of tests performed.
View: Select VIEW to display the number of tests since the counter
was last reset to 0 and the total number of tests.
Clear: Select CLEAR to reset the counter to 0. The Test Counter
screen will display the value of 0.
H. Main Menu
Select this utility option to return to the first option, PRINT RE-
SULTS, in the Main menu.

TROUBLESHOOTING TEST PROBLEMS

If the display does not turn on:
Check the connection to the battery.
The battery may be too low to power the analyzer (below 1.0 volts).
Fully charge the battery and retest.
The analyzer's internal 9-volt battery may need to be replaced. See
"Replacing the Analyzer Battery."
SURFACE CHARGE DETECTED: The battery will hold a surface
charge if the engine has been running or after the battery has been
charged. The analyzer may prompt you to remove the surface charge
before it begins testing.
1. Follow the instructions on the display.
2. After detecting the removal of the surface charge, the tester will
resume testing.
SYSTEM NOISE / CHECK LOADS: The analyzer has detected com-
puter or ignition noise and will attempt to retest. Make sure all vehicle
loads are off and the ignition is in the off position. The analyzer will
automatically retest when it no longer detects system noise.
You may be testing too close to a noise source, i.e., a charger or
other high-current device. If so, move away and retest.
If no noise source is identified, fully charge the battery and retest.
If the message appears after recharging, replace the battery.
Disconnect the battery cables and retest.
E
NGLISH
14