Pushing/Pulling Machine

IMPORTANT: If push/pull limits are exceeded, se -
vere damage to the piston (traction) pump may oc -
cur.
If it becomes necessary to push/pull the machine, push/
pull at a speed below 1 mph (1.6 kph), and for a dis-
tance less than 100 feet (30.5 meters). The piston
(traction) pump is equipped with a by–pass valve that
needs to be rotated counterclockwise (loosened) one
turn for pushing/pulling. The by–pass valve should be
torqued from 95 to 120 in–lb (10.7 to 13.6 N–m) before
the machine is returned to operation.
See Operator's Manual for pushing/pulling procedures.

Check Hydraulic Fluid

The ProCore 648 hydraulic system is designed to oper -
ate on anti–wear hydraulic fluid. The reservoir (Fig. 8)
holds about 1.75 gallons (6.6 liters) of hydraulic fluid.
Check level of hydraulic fluid daily.
See Operator's Manual for fluid level checking proce-
dure and hydraulic oil recommendations.

Relieving Hydraulic System Pressure

Before disconnecting or performing any work on the hy-
draulic system, all pressure in the hydraulic system
must be relieved. With the coring head fully raised, turn
key switch to OFF and allow engine to stop. Secure cor-
ing head with service latch.
To relieve hydraulic pressure in traction circuit, move
traction lever to both forward and reverse directions.
Hydraulic System
2
1. Hydraulic reservoir
To relieve lift system pressure, turn key switch to ON
(engine not running). Move traction lever to forward di -
rection and depress lower switch on handle to lower cor-
ing head onto service latch. Return key switch to OFF
when pressure has been relieved. Remove key from the
ignition switch.
Page 4 – 6
1
Figure 7
1. By–pass valve location
Figure 8
2. Hydraulic reservoir cap
1
ProCore 648