Removal (Fig. 38)
1. Park machine on a level surface, fully raise coring
head, engage parking brake, stop engine and remove
key from the ignition switch. Secure coring head with
service latch.
CAUTION
Operate all hydraulic controls to relieve system
pressure and avoid injury from pressurized hy-
draulic oil. See Relieving Hydraulic System Pres-
sure in the General Information section of this
chapter.
NOTE: The ports on the manifold are marked for easy
identification of components. Example: P is the pump
connection port and R1 is the location for the relief valve
(See Hydraulic Schematic to identify the function of the
hydraulic lines and cartridge valves at each manifold
port location).
2. Disconnect solenoid valve electrical connectors.
NOTE: The hydraulic reservoir will drain when the hy-
draulic oil filter is removed from the hydraulic manifold.
3. Clean area around hydraulic filter mounting area.
Remove filter from hydraulic manifold and drain reser-
voir into a suitable container. Discard filter.
4. Clean manifold and hydraulic connections. Discon-
nect hydraulic lines. Label all connections for assembly.
5. Allow hydraulic lines to drain into a suitable contain-
er. Put caps or plugs on disconnected hoses and fittings
to prevent contamination. Discard any removed o–
rings.
6. Remove two (2) cap screws and flange nuts that se-
cure hydraulic manifold to the frame mounting bracket.
7. Remove hydraulic manifold from the machine.
8. Remove hydraulic fittings from manifold as needed
(Fig. 39).
Installation (Fig. 38)
1. Position hydraulic manifold to the frame mounting
bracket. Install two (2) cap screws and flange nuts but
do not tighten.
2. Make sure all hydraulic connections, ports and fit-
tings are clean.
ProCore 648
3. Remove caps or plugs that were put on any hydraulic
lines or fittings during disassembly.
4. Lightly oil new o–rings for hydraulic fitting and hose
locations.
5. Correctly connect hydraulic fittings and lines to the
manifold. Tighten all hydraulic fittings and connections.
6. Secure hydraulic manifold by tightening two (2) cap
screws and flange nuts.
7. Reconnect solenoid valve electrical connectors.
8. Follow Hydraulic System Start–up procedures.
10
2
3
4
9
7
8
1. Hydraulic manifold
2. O–ring
3. Hydraulic fitting
4. O–ring
5. O–ring
6. Hydraulic fitting
7. O–ring
Page 4 – 47
5
6
2
3
4
Figure 39
8. Barbed fitting
9. O–ring
10. Hydraulic oil filter
11. Dust cap (2 used)
12. Quick fitting (2 used)
13. O–ring (2 used)
Hydraulic System
11
12
13
1

Advertisement