Bench And Function Tests; Setting Parameters - ABB CP410 Installation And Operation Manual

Table of Contents

Advertisement

Operation
7.4

Bench and Function Tests

Set dip switches SW3 and SW4 = OFF to be able to run the bench and function
tests for the CP410. Turn on the operator terminal to display the following
screen:
The following items are tested:
CP410
F9 - Bench test
F6 - Function Test
7.5

Setting Parameters

There are two ways to configure working parameters; to set parameters in the
operator terminal or in CP400Soft.
To set parameters in the operator terminal, select F7 - Confg in the system
menu.
Note:
Remember to set dip switch SW5 = ON if parameters are set in the operator ter-
minal.
To set parameters in CP400Soft, select Application/Workstation Setup. Select
the Connection tab to set communication parameters.
Note:
Remember to set dip switch SW5 = OFF if parameters are set in CP400Soft.
18
Keyboard Test: 16 keys
BIOS: System RAM, Flash memory, Buzzer, LED, BIOS, Battery
Status, RTC, COM port, Flash ROM
F1: LED
F2: Buzzer
F3: DIP SW
F4: LCD
Description
F5: RS232
F6: RS422
F7: RS485
F8: KEY
ABB, 1SBC159101M0201

Advertisement

Table of Contents
loading

Table of Contents