CP410
Installation and Operation Manual
English
ABB, 1SBC159101M0201 2007-05

Advertisement

Table of Contents
loading

Summary of Contents for ABB CP410

  • Page 1 CP410 Installation and Operation Manual English ABB, 1SBC159101M0201 2007-05...
  • Page 2 Document number: ABB, 1SBC159101M0201 Please read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. ABB is not responsible for modified, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications.
  • Page 3: Table Of Contents

    7 Operation ..................... 15 Self Test ..................15 System Menu ................16 Key Pad..................17 Bench and Function Tests ............18 Setting Parameters..............18 Downloading an Application ............. 19 Uploading an Application ............20 Copying an Application ............. 21 Passwords................... 22 ABB, 1SBC159101M0201...
  • Page 4 Contents ABB, 1SBC159101M0201...
  • Page 5: Safety Precautions

    – The supplier neither guarantees that the operator terminal is suitable for your particular application, nor assumes responsibility for your product design, in- stallation or operation. ABB, 1SBC159101M0201...
  • Page 6: Service And Maintenance

    Dismantling and Scrapping – The operator terminal or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. ABB, 1SBC159101M0201...
  • Page 7: Installation

    Installation Installation Package Contents The following parts are found in the box: – Operator terminal CP410 CP410 – 4 installation fasteners – Power connector (connected to the 24 V DC power outlet) – This installation and operation manual (1SBC159101M0201) ABB, 1SBC159101M0201...
  • Page 8: Product Specifications

    Product Specifications Product Specifications Parameter CP410 Front panel, W x H x D 173.0 x 105.5 x 5.8 mm Mounting depth 51.8 mm Cut-out dimensions 160.8 x 93.3 mm Front panel protection IP 65/NEMA 4 Keypad specifications 16 mechanical switches. Lifetime of each switch is over 500,000 activations.
  • Page 9: Description Of Parts

    Product Specifications Parameter CP410 RF Emissions CISPR 22, Class A Electrostatic Discharge IEC61000-4-2 RF Susceptibility IEC61000-4-3 High Frequency Transients IEC61000-4-4 Cooling Natural cooling Description of Parts Front Fixture mounting holes Power lamp Communication lamp Function and numerical keys Display Back...
  • Page 10: External And Cut-Out Dimensions

    Product Specifications External and Cut-out Dimensions CUTOUT DIMENSION UNIT: mm CP410 Mounting Procedure 1. Cut out the control front panel to match the dimensions (mm) below. ABB, 1SBC159101M0201...
  • Page 11 STEP 1 STEP 2 STEP 3 Maximum torgue: 0.3 Nm ° 3. The operator terminal is to be installed within the angle of 0 to 135 shown below. ABB, 1SBC159101M0201...
  • Page 12: Grounding

    To make sure that the operator terminal works properly and to prevent it from radiating radio frequency noise, it must be connected to the earth ground. Power Supply and Wiring CP410 must use the power supply with 24 V DC and the power consumption is 8 W. Warning: To avoid an electrical shock, be sure to switch off the power before connecting the communication/download cable to the operator terminal.
  • Page 13: Dip Switches

    Reserved (no function) SW10 Com2 Port For RS485, this switch has to be set ON. For RS422, this switch has to be set OFF. For RS232, this switch has no effect. ABB, 1SBC159101M0201...
  • Page 14: Communication Port

    LCD Contrast Adjustment The potentiometer on the back of the operator terminal is used to adjust LCD Contrast (STN LCD). Use a small screwdriver to turn the potentiometer (clock- wise = contrast down; counter-clockwise = contrast up). ABB, 1SBC159101M0201...
  • Page 15: Operation

    After downloading again, all items should pass the self-test. Note: When using the operator terminal for the first time, remember to reset the real time clock (RTC). ABB, 1SBC159101M0201...
  • Page 16: System Menu

    Sets up the internal time clock and communication parameters in the operator terminal. to move to desired field and to set the value of the field. F8 - Copy Copies application data to another CP410. F9 - Run Runs the application. ABB, 1SBC159101M0201...
  • Page 17: Key Pad

    Operation Key Pad The CP410 has 16 keys, that can be categorized into Numerical Keys, Navigation Keys and Functional Keys. CP410 Functional keys F1-F10 Numerical keys Navigation keys The Functional or Auxiliary Keys F1- F10 can be defined in CP400Soft. They can, for example, be used to set a controller bit or register, to change a screen or to display a password table.
  • Page 18: Bench And Function Tests

    Bench and Function Tests Set dip switches SW3 and SW4 = OFF to be able to run the bench and function tests for the CP410. Turn on the operator terminal to display the following screen: The following items are tested:...
  • Page 19: Downloading An Application

    Operation Downloading an Application Connect the RS232 port on the PC to the COM2 port on the CP410 using a TK401 cable. The connection can also be made according to the the illustration below: 9-pin male 9-pin female RXD 2...
  • Page 20: Uploading An Application

    *.V6F file. Thus a source file can serve the purposes of maintenance and modification. Note: When uploading for the first time, make sure to first run the application once, or else the upload function will not work. ABB, 1SBC159101M0201...
  • Page 21: Copying An Application

    Operation Copying an Application To copy an application from one CP410 to another CP410, select F8 - Copy from the system menu. Set the dip switch SW7 = ON and connect the two op- erator terminals with a download cable using COM2. After the self-test, the sys- tem menu will be displayed on the screen.
  • Page 22: Passwords

    After registering passwords and user levels, set the dip switch SW6 = ON (i.e. password required). Restart the operator terminal and after the self-test the user will be prompted to enter a password in order to run the operator terminal. ABB, 1SBC159101M0201...
  • Page 23 The user will need a password with at least the level of privilege that has been set for the button. This function can restrict users to ac- cess to certain parts of the application. ABB, 1SBC159101M0201...
  • Page 24 When selecting F8 - Copy in the system menu or File/Upload Application in CP400Soft, the operator terminal will prompt for a password. The user will need to enter the correct password to copy an application from one CP410 to another. Note that setting this password is different from the passwords set in Scenario 1-3.