Dip Switches - ABB CP410 Installation And Operation Manual

Table of Contents

Advertisement

4

Dip Switches

Dip switch
SW1
SW2
SW3
SW4
ON
ON
ON
OFF
OFF
ON
OFF
OFF
SW5
ON
OFF
SW6
ON
OFF
SW7
ON
OFF
SW8
ON
OFF
SW9
SW10
ON
OFF
ABB, 1SBC159101M0201
Reserved
Reserved
Operation Mode
Runs user application
Runs burn-in test program
Updates BIOS
Runs bench test program
Communication Parameters
The operator terminal uses the communication parameters
defined on the operator terminal's configuration screen for
controller communication.
The operator terminal uses the communication parameters
defined in CP400Soft for controller communication.
Password
The operator terminal asks the operator to enter a password
after power-on self-test.
No password is required to start the operator terminal.
System Menu
The operator terminal displays the system menu.
The operator terminal runs user application without displaying
the system menu.
Default User Level
The default user level is set to 1 if the operator terminal
requires no password to start its operation.
The default user level is set to 9 if the operator terminal
requires no password to start its operation.
Reserved (no function)
Com2 Port
For RS485, this switch has to be set ON.
For RS422, this switch has to be set OFF.
For RS232, this switch has no effect.
Function
Dip Switches
13