Thermistor - Resistance Chart; Fault Notes; Filling; Heating Element - Hotpoint FDYF11011K Service Information

Freestanding dishwasher with digit display
Table of Contents

Advertisement

Indesit
Company

Thermistor - Resistance Chart

Temperature
Resistance
in degrees C
in K Ohms
- 40
24751.661
- 35
17127.169
- 30
12014.762
- 25
8524.305
- 20
6113.811
- 15
4435.437
- 10
3249.216
- 5
2403.515
0
1794.358
+ 5
1351.294
10
1025.870
15
785.018
20
605.252
25
470.000
30
367.480
35
289.186
40
229.014
45
182.485

Fault Notes

Filling

After the initial drain period, it is normal at the start of a cycle for the machine to pause for a period
before filling.

Heating Element

An open circuit heating element can display either the heating time out fault code or the open
circuit heater fault code (F8 & F10), depending on the cycle in progress or the phase of the cycle
when the heater fails.
If a dishwasher has an open circuit heating element, the machine may run for up to 75 minutes
before a fault code will display.
It is recommended before a module is replaced or when the fault is not obvious, the heating
element is tested for continuity and resistance to Earth at its terminals, with the heater
disconnected.
continued...
Service Manual UK
Temperature
Resistance
in degrees C
in K Ohms
50
146.215
55
117.828
60
95.420
65
77.718
70
63.584
75
52.260
80
43.166
85
35.808
90
29.828
95
24.961
100
20.955
105
17.668
110
14.951
115
12.695
120
10.824
125
9.259
7 of 39