prObLEM
ENgiNE OpErATES
fOr 15 MiN. THEN
STOpS
ENgiNE LAckS
pOwEr
ENgiNE fALTErS
wATEr DrippiNg
frOM
UNDEr pUMp
OiL DrippiNg
wATEr LEAkiNg
frOM pUMp prOTEc-
TOr
NO DETErgENT
gArDEN HOSE
cONNEcTiON LEAkS
SprAY wAND LEAkS
pUMp iS NOiSY
26

TrOUbLESHOOTiNg

pOSSibLE cAUSE
Not enough gas or engine oil
Vapor lock developed by heat of
day
Obstruction in fuel filter
Dirty air filter
Choke is opened too soon
Piston packing worn
O-Ring plunger retainer worn
Cracked piston
Oil seal worn or damaged
Spray gun closed with machine
running 5 minutes or longer
Excess water supply pressure
Detergent suction tube not prop-
erly connected to machine
Detergent is too thick
Detergent filter valve is at lowest
setting
Filter on detergent suction tube is
clogged
Damaged or clogged detergent
suction tube
a high pressure nozzle is at-
tached.
Discharge nozzle is obstructed
Loose fittings
Missing/worn rubber washer
Spray wand not properly attached Slide the spray wand into the gun. Turn the
Broken o-ring
Pump is sucking air
9.800-414.0 • Rev. 11/09
SOLUTiON
Fill tank with gas. Check oil level.
Keep gas tank full to avoid vapor locking.
Clean or replace fuel filter.
Replace air filter.
Move choke to halfway position until engine
runs smoothly.
Contact local dealer or technical support.
Contact local dealer or technical support.
Contact local dealer or technical support.
Contact local deale or technical support r.
Open spray gun or turn off machine.
Place a pressure regulator at end of 50'
garden hose.
Check connection.
Dilute detergent. For best results, use our
detergent.
Set detergent filter valve to a higher setting.
Run warm water through filter to remove
debris.
Remove obstruction or replace detergent
suction tube.
Replace with black detergent nozzle.
Blow out or remove debris with fine needle.
Tighten fittings.
Insert new washer.
wand collar clockwise onto the spray gun
threads until tight.
Contact local dealer to order an o-ring.
Check that hoses and fittings are air tight.
Turn off machine and purge pump by
squeezing trigger gun until a steady flow of
water emerges through nozzle.