ERROR CODES & POSSIBLE CAUSES
When an error occurs the following LEDs will flash indicating a fault.
Refer to the chart below for the error code definitions.
F01
Motor triac short circuit: Check motor and module connections
F02
Motor jammed / tacho detached: Check motor and module connections
F03
NTC short/open circuit: Check thermistor and module connections
F04
Pressure switch jammed on empty: Check switch and module
F05
Pressure switch jammed on full or pump blocked: Check pump and switch
F06
N/A
F07
Heater relay stuck: Check heater and module connections
F08
Heater relay stuck: Check pressure switch, heater and module connections
F09
Setup error: Check Eeprom
F10
Pressure switch not sensing: Check switch and module connections
F11
Pump cannot be activated: Check pump, connections and wiring
F12
No communication between cards: Check module connections
High temperature Rise In Drying: Reduced air flow through dryer heater
F13
assembly.
Check operation of fan motor and dryer filter for blockage
No Heat In Drying: Check one shot thermostat. Check heater, valve and fan
F14
motor module connections. Edge connector J10
F15
No Drying: Possibly dryer relay open circuit
F16
N/A
F17
Door lock error: Check door, door lock and module connections
F18
Communication error (3 phase motor): Replace power board
Service Manual UK
FAULT
LED 5
LED 4
F01
F02
LED 3
F03
LED 2
F04
F05
LED 1
F06
F07
F08
F09
F10
F11
F12
F13
F14
F15
F16
F17
F18
LED COMBINATION
LED 5
LED 4
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
On
Off
On
Off
On
Off
16 of 26
LED 3
LED 2
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On
On
On
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On
On
On
Off
Off
Off
Off
Off
On
English
LED 1
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
Need help?
Do you have a question about the ARMXXL125EU and is the answer not in the manual?