Siemens QAA73.210 User Manual page 17

Room unit for boiler control with opentherm interface
Table of Contents

Advertisement

ECO24
KORR
BUILD
AMBON
QSETB
SDR
HC2SR
2)
HC2SF
2)
COOL 1)
COMFR
ECONM
DHW
COMFR
ECONM
SHOWR
HW MX
HW MN
L FCT
L TIME
L TEMP
CONF
HW PR
COOL
RESET
Siemens
Building Technologies
F
24-hour heating limit
F
Room influence
F
Time constant building
F
Room influence ON/OFF
0 = OFF, 1 = ON
F
Quick setback ON/OFF
0 = OFF, 1 = ON
F
Room temp limitation
F
Room temperature setpoint for
heating circuit 2
F
Flow temperature setpoint heating
circuit 2
E
Comfort setpoint
E
Reduced setpoint
F
Nominal setpoint
F
Reduced setpoint
O
Shower function setpoint
F
DHW setpoint max
F
DHW setpoint min
F
Legionella function
0 = OFF, 1 = ON
F
Legionella function dwelling time
F
Setpoint of legionella function
F
DHW program
F
COOLING ON/OFF
0 = OFF, 1 = ON
O
Reset to default parameters
0 = NO, 1 = YES
1) This menu is only visible if parameter COOL is ON
2) Only active when supported by BMU
Room Unit for Boiler Control
Handling
0
-10...+10
4
0...20
3
0...10
1
0-1
1
0-1
0,5
0,5...4,0
20
5...35
80
20...80
22
5...30
24
5...30
55
35...70
35
35...70
40
35...70
65
35...70
35
35...70
0
0...2
1
1...180
65
35...70
1
0...2
0
0-1
0
0-1
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
Min
°C
17 / 36
CE1U2283en
2015-09-16

Hide quick links: