Siemens QAA73.210 User Manual page 13

Room unit for boiler control with opentherm interface
Table of Contents

Advertisement

Displaying information
Indication of faults
Other fault displays
Siemens
Building Technologies
Various data can be displayed by pressing the info button.
Depending on the type of unit, configuration and operating state,
some of the info lines listed below may not appear.
Display:
Description
- Boiler temperature
- Water pressure
- Outside temperature
- Domestic hot water temperature
- Domestic hot water temperature 2
- Domestic hot water flow rate
- Relative boiler power
- Fan speed
- Exhaust temperature
- Return temperature
- Calculated flow temperature setpoint
During boiler operation it is
possible to see the actual
boiler modulation level on 4
different levels.
The room unit indicates faults that may have occurred in the unit itself or in the
system
If a fault is indicated 'ERROR' and the error code followed by the letter 'E' are
visualized in the display.
These faults cannot be reset. They will be cleared only when rectified.
Error code
Description
60
Room sensor
88
Communication
95
Clock
127
Legionella setpoint not reached 1)
1) Can be reset by pressing OK button
Depending on the type of boiler control, the room unit also displays other error
codes. For detailed information, please refer to the technical documentation of the
boiler controller used.
Room Unit for Boiler Control
Handling
Name
Unit
BOILR
°C
P BAR
Bar
EXT T
°C
DHW
°C
DHW 2
°C
DHWFR
l/min
PWR
%
S FAN
Rpm
T EXH
°C
RETUR
°C
CH SP
°C
i
13 / 36
CE1U2283en
2015-09-16