Fujitsu AUU7RLF Design & Technical Manual page 54

Multi: 5 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

Model name
Power supply
Available voltage range
Capacity
Input power
Running current
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Cooling
Sound pressure level *
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Liquid
Size
Connection pipe
Gas
Method
Material
Drain hose
Size
Cooling
Operation range
Heating
Remote controller type
NOTES:
•The protective function might work when using it outside the operation range.
•*Sound pressure level:
–Measured values in manufacturer's anechoic chamber.
–Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Btu/h class
W
A
HIGH
MED
LOW
QUIET
3
CFM (m
/h)
HIGH
MED
LOW
QUIET
W
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
in (mm)
FPI
in (mm)
lb (kg)
mm (in)
in (mm)
°F (°C)
%RH
°F (°C)
- 48 -
ASU18RLF
208/230 V ~ 60 Hz
187—264 V
18,000
41
0.32
542 (920)
436 (740)
365 (620)
324 (550)
542 (920)
436 (740)
365 (620)
324 (550)
Cross flow fan ×1
42
43
37
33
31
44
37
33
31
Main: 15-7/8 × 33-3/4 × 1-1/16 (378 × 832 × 26.6)
Sub: 3-5/16 × 33-3/4 × 1/2 (84 × 832 × 13.3)
Main: 21, Sub: 18
Main: 2 × 18, Sub: 1 × 4
Copper tube
Aluminum
Polystyrene
White
(Approximate color of MUNSELL N9.25 /)
12-5/8 × 39-1/4 × 9 (320 × 998 × 228)
12-9/16 × 42-15/16 × 16-7/8 (319 × 1,090 × 429)
31 (14)
40 (18)
Ø1/4 (Ø6.35)
Ø1/2 (Ø12.70)
Flare
PVC
Ø 1/2(I.D.), Ø 5/8(O.D.) [Ø 12(I.D.), Ø 16(O.D.)]
64 to 90 (18 to 32)
80 or less
60 to 88 (16 to 31)
Wireless (Wired [option])
ASU24RLF
24,000
69
0.53
659 (1,120)
530 (900)
436 (740)
365 (620)
647 (1,100)
530 (900)
436 (740)
365 (620)
49
42
37
33
48
42
37
33
Ø5/8 (Ø15.88)

Hide quick links:

Advertisement

Table of Contents
loading