Wireless Remote Controller (Ar-Reg1U) - Fujitsu AUU7RLF Design & Technical Manual

Multi: 5 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

2-2. Wireless remote controller (AR-REG1U)

 Features
REG1U
 Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
 Program timer
The program timer operates the on and off timer once within a 24-hour period.
 Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/Dry operation
When the sleep timer is set, the set temperature
automatically rises 2 °F (1 °C) every hour. The
set temperature can rise up to a maximum of 4 °F
(2 °C).
60 min
 Switching remote controller custom code
Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.)
* I.U.: Indoor unit
 Temperature unit switchable
Easy to change the temperature unit between °F and °C by button operation.
• 4-mode timer setup (on, off, program, and sleep) available.
• Easy operation.
• Easy to change custom code (max. 4 custom code).
• Can be used jointly with wired remote controllers.
Timer setting
4 °F (2 °C)
2 °F (1 °C)
Mixed-up
I.U.
I.U.
I.U.
I.U.
- 21 -
Heating operation
When the sleep timer is set, the set temperature
automatically drops 2 °F (1 °C) every 30 minutes.
The set temperature can drop to a maximum of 8
°F (4 °C).
2°F (1°C) 4°F (2°C)
30 min
60 min
90 min
Timer setting
After code change
A
B
C
D
I.U.
I.U.
I.U.
I.U.
A
B
C
D
6°F (3°C)
8°F (4°C)