11. Safety devices

Indoor unit
Model name
type
AUU7RLF
Compact
AUU9RLF
cassette
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
Slim duct
ARU12RLF
ARU18RLF
ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
Wall mounted
ASU18RLF
ASU24RLF
AGU9RLF
Floor
AGU12RLF
AGU15RLF
*: Printed Circuit Board
Fan motor thermal
PCB* fuse
protector
Activate: 212 ± 27 °F
(100 ± 15 °C)
Fan motor stop
250 V, 3.15 A
Reset: 203 ± 18 °F
(95 ± 10 °C)
Fan motor restart
Activate: 275 ± 27 °F
(135 ± 15 °C)
Fan motor stop
250 V, 3.15 A
Reset: 239 ± 27 °F
(115 ± 15 °C)
Fan motor restart
Activate: 221 ± 18 °F
(105 ± 10 °C)
Fan motor stop
250 V, 3.15 A
Reset: 194 ± 18 °F
(90 ± 10 °C)
Fan motor restart
Activate: 302 ± 27 °F
(150 ± 15 °C)
Fan motor stop
250 V, 3.15 A
Reset: 248 ± 27 °F
(120 ± 15 °C)
Fan motor restart
Activate: 302 ± 27 °F
(150 ± 15 °C)
Fan motor stop
250 V, 3.15 A
Reset: 248 ± 27 °F
(120 ± 15 °C)
Fan motor restart
- 118 -
Terminal thermal
Float
fuse
switch
Activate: 216 °F
(102 °C)
Activate: 216 °F
(102 °C)