Ground - Mitsubishi Electric City Multi PUMY-SP112VKM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for City Multi PUMY-SP112VKM:
Table of Contents

Advertisement

Check code
High pressure trouble
1302
(UE)
Chart 4 of 4
●Diagnosis of defectives
Make sure to turn the power OFF before connecting/disconnecting any connectors, or replacing boards.
Diagnosis
Remedy
Continued from the previous page
Is there a resistance detected?
Replace the SV1.
No
Yes
Is the connector for outdoor
multi controller circuit board 63H
Reconnect the connector or connect it tightly.
Yes
disconnected or loose?
No
Check the 63HS voltage.
Is there a voltage(*) detected?
Replace the 63HS.
No
*For the voltage, refer to "8-6. HOW
Yes
TO CHECK THE COMPONENTS".
Replace the outdoor multi controller circuit
board.
56
OCH668B