Specifications - Mitsubishi Electric City Multi PUMY-SP112VKM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for City Multi PUMY-SP112VKM:
Table of Contents

Advertisement

3

SPECIFICATIONS

Model
Power source
Cooling capacity
(Nominal)
Power input
Current input A
COP
Temp. range of cooling Indoor temp.
Outdoor temp. D.B.
Heating capacity
(Nominal)
Power input
Current input A
COP
Temp. range of heating Indoor temp.
Outdoor temp. W.B.
Indoor unit
Total capacity
connectable
Model/
Quantity
Sound pressure level
(measured in anechoic room)
Power pressure level
(measured in anechoic room)
Refrigerant piping
Liquid pipe
diameter
Gas pipe
*2
FAN
Type × Quantity
Air flow rate
Control, Driving mechanism
Motor output
External static press.
Compressor
Type × Quantity
Manufacturer
Starting method
Capacity control %
Motor output
Case heater
Lubricant
External finish
External dimension H × W × D
Protection devices
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Fan motor
Refrigerant
Type × original charge
Control
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Drawing
External
Wiring
Standard attachment
Document
Accessory
Optional parts
Remarks
*1 Nominal cooling conditions
Indoor:
27°C D.B./19°C W.B. [81°F D.B/66°F W.B.]
Outdoor:
35°C D.B. [95°F D.B.]
Pipe length:
7.5 m [24-9/16 ft]
Level difference:
0 m [0 ft]
*3 10 to 52°C(D.B):, when connecting following models: PKFY-P15/20/25VBM, PFFY-P20/25/32VLE(R)M, PFFY-P20/25/32VKM, and
M series , S series , and P series type indoor unit with branch box , M series type indoor unit with connection kit.
*4 −15 to 52°C(D.B):, when using an optional air protect guide [PAC-SH95AG-E]. However, this condition does not apply to the indoor unit listed
in *3.
*5 Up to P100 when connecting via branch box.
*6 Up to 11 units when connecting via 2 branch boxes.
*7 When connecting 7 indoor units via branch box, connectable citymulti indoor units are 3; connecting 8 indoor units via branch box, connectable citymulti indoor units are 2.
*8 94 (207), for PUMY-SP112/125/140VKM(R1).TH-BS.
Notes :1. Nominal conditions *1, *2 are subject to ISO 15042.
2. Due to continuing improvement, above specifications may be subject to change without notice.
OCH668B
*1
kW
*1
kcal/h
*1
BTU/h
kW
kW/kW
W.B.
*2
kW
*2
kcal/h
*2
BTU/h
kW
kW/kW
D.B.
City multi
Branch box
"Mixed
Branch box
City multi
system"
1 unit
Branch
box
Branch box
City multi
2 units
Branch
box
dB <A>
dB <A>
mm (inch)
mm (inch)
m³/min
L/s
cfm
kW
kW
kW
mm
inch
kg (lb)
*2 Nominal heating conditions
20°C D.B. [68°F D.B.]
7°C DB/6°C W.B. [45°F D.B./43°F W.B.]
7.5 m [24-9/16 ft]
0 m [0 ft]
PUMY-SP112VKM(R1).TH(-BS)
PUMY-SP125VKM(R1).TH(-BS)
1-phase 220-230-240 V, 50 Hz; 1-phase 220 V, 60 Hz
220
230
240
220
50/60
50
50
50/60
12.5
10,750
42,650
3.10
14.38
13.75
13.18
17.81
4.03
14.0
12,040
47,768
3.17
14.70
14.06
13.48
18.09
4.42
50 to 130% of outdoor unit capacity
15-140/9
15-100/8
15-140/5
15-100/5
*7
15-140/3 or 2
*7
15-100/7 or 8
52/54
72/74
77
1283
2719
Twin rotary hermetic compressor × 1
Mitsubishi Electric Corporation
Cooling 26 to 100
Heating 20 to 100
3.1
Galvanized Steel Sheet Munsell No. 3Y 7.8/1.1
981 × 1,050 × 330(+40)
38-5/8 × 41-3/8 × 13 (+1-37/64)
High pressure Switch
Overcurrent detection, Overheat detection(Heat sink thermistor)
Compressor thermistor, Overcurrent detection
Overheating, Voltage protection
Electronic expansion valve
Cross Fin and Copper tube
Reversed refrigerant circuit
Installation Manual
Grounded lead wire × 2
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
9
PUMY-SP140VKM(R1).TH(-BS)
230
240
220
50
50
50/60
14.0
12,040
47,768
3.84
17.04
16.33
21.80
3.65
15 to 24°C
*3,*4
-5 to 52°C
16.0
13,760
54,592
3.90
17.30
16.58
18.65
4.10
15 to 27°C
-20 to 15°C
15-140/10
15-140/12
15-100/8
15-100/8
15-140/5
15-140/5
15-100/5
15-100/5
15-140/3
15-140/3
15-100/8
15-100/8
53/56
73/76
9.52 (3/8)
15.88 (5/8)
Propeller Fan × 1
83
1383
2931
DC control
0.20 × 1
0
Inverter
Cooling 24 to 100
Cooling 21 to 100
Heating 18 to 100
Heating 17 to 100
3.5
0
FV50S (1.4litter)
R410A 3.5 kg
*8
93 (205)
HIC circuit
RK01B171
BH79J995
Unit converter
kcal/h = kW × 860
BTU/h = kW × 3,412
cfm = m³/min × 35.31
lb = kg/0.4536
Above specification data is
subject to rounding variation.
230
240
50
50
15.5
13,330
52,886
4.70
20.85
19.98
3.30
16.5
14,190
56,298
4.02
17.83
17.09
4.10
54/56
74/76
83
1383
2931
3.7