OVERVIEW OF UNITS

2-1. UNIT CONSTRUCTION
Outdoor unit
Applicable
Capacity
indoor unit
Number of units
Total system capacity range
Model
Cassette Ceiling
4-way flow
2 by 2
PLFY-P PLFY-P PLFY-EP*
Capacity
15VFM-E1
15
20VFM-E1
20VEM-E
20
25VFM-E1
25VEM-E
25
32VFM-E1
32VEM-E
32
40VFM-E1
40VEM-E
40
50VFM-E1
50VEM-E 50VEM-E 50VLMD-E
50
63VEM-E 63VEM-E 63VLMD-E
63
71
80VEM-E 80VEM-E 80VLMD-E
80
100VEM-E
100
125VEM-E
125
140
Remote
controller
*1
W hen the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110%.
*2
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*3
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
4
*
Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*5
Authorized connectable indoor units are as follows;
PUMY-SP112:PEFY-P25VMA3-E×2 + PEFY-P32VMA3-E×2
PUMY-SP125: PEFY-P25VMA3-E×1 + PEFY-P32VMA3-E×3
PUMY-SP140: PEFY-P32VMA3-E×2 + PEFY-P40VMA3-E×2
*6
For the PLFY-EP/VEM-E, up to 2 units can be connected . Other indoor units (Excluding the PEFY-P/ VMA3-E and PEFY-P/ VMH-EF) can
be connected within the total rated capacity and maximum number of connected units.
*7
C onnectable only for PUMY-SP▪VKMR1.TH(-BS),PUMY-SP▪YKMR1.TH(-BS).
OCH668B
4.5HP
PUMY-SP112VKM(R1).TH(-BS)
PUMY-SP112YKM(R1).TH(-BS)
1 to 9 units
50 to 130% of outdoor unit cap50 to 130% of outdoor unit capacity *
CMY-Y62-G-E
Branching pipe
Branch header
components
(2 branches)
Ceiling
concealed
2-way flow 1-way flow
6
PLFY-P PMFY-P
PEFY-P
15VMS1(L)-E
20VMS1(L)-E
20VLMD-E 20VBM-E
20VMA(L)-E
20VMR-E-L/R
25VMS1(L)-E
25VMA(L)-E
25VLMD-E 25VBM-E
25VMR-E-L/R
5
25VMA3-E*
32VMS1(L)-E
32VMA(L)-E
32VLMD-E 32VBM-E
32VMR-E-L/R
5
32VMA3-E*
40VMS1(L)-E
40VMA(L)-E
40VLMD-E 40VBM-E
40VMH(S)-E
40VMA3-E*
5
50VMS1(L)-E
50VMA(L)-E
50VMH(S)-E
63VMS1(L)-E
63VMA(L)-E
63VMH(S)-E
71VMA(L)-E
71VMH(S)-E
80VMA(L)-E
80VMH(S)-E
100VMA(L)-E
100VLMD-E
100VMH(S)-E
125VMA(L)-E
125VLMD-E
125VMH(S)-E
140VMA(L)-E
140VMH(S)-E
Name
M-NET remote controller
Model number
PAR-F27MEA-E, PAR-U02MEDA
• A handy remote controller for use in
conjunction with the Melans centralized
Functions
management system.
• Addresses must be set.
5HP
PUMY-SP125VKM(R1).TH(-BS)
PUMY-SP125YKM(R1).TH(-BS)
Type 15 to Type 140
1 to 10 units
CMY-Y64-G-E
Branch header
(4 branches)
Floor standing
Ceiling
Wall
Suspended
Mounted
Exposed Concealed Fresh air *
PKFY-P
PCFY-P PFFY-P PFFY-P PEFY-P PDFY-P
15VBM-E
20VLEM-E
20VLRM-E
20VBM-E
20VKM-E(2)
20VLRMM-E
25VLEM-E
25VLRM-E
25VBM-E
25VKM-E(2)
25VLRMM-E
32VLEM-E
32VLRM-E
32VHM-E
32VKM-E(2)
32VLRMM-E
40VLEM-E
40VLRM-E
40VHM-E
40VKM-E
40VKM-E(2)
40VLRMM-E
50VLRM-E
50VHM-E
50VLEM-E
50VLRMM-E
63VLRM-E
63VKM-E
63VKM-E 63VLEM-E
63VLRMM-E
100VKM-E 100VKM-E
125VKM-E
MA remote controller
PAR-21MAA, PAR-31/32MAA
• Addresses setting is not
necessary.
5
PUMY-SP140VKM(R1).TH(-BS)
PUMY-SP140YKM(R1).TH(-BS)
1 to 12 units
1
acity *250 to 130% of outdoor unit capacity *2
CMY-Y68-G-E
Branch header
(8 branches)
Ceiling concealed
Lossnay
2
Built-in
4
GUF*
20VM-E
25VM-E
32VM-E
40VM-E
50VM-E
50RD(H)4
63VM-E
71VM-E
80VMH-E-F 80VM-E
100VM-E 100RD(H)4
125VM-E
140VMH-E-F
6HP
CONNECTION KIT
PAC-LV11M-J
M series indoor unit *
3
MSZ-GE Series
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MSZ-LN Series
7
MSZ-AP Series *
M series remote
controller