Wiring Diagram - Mitsubishi Electric City Multi PUMY-SP112VKM Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for City Multi PUMY-SP112VKM:
Table of Contents

Advertisement

WIRING DIAGRAM

6
PUMY-SP112VKM(R1).TH
PUMY-SP112VKM(R1).TH-BS PUMY-SP125VKM(R1).TH-BS PUMY-SP140VKM(R1).TH-BS
MULTI. B.
MF1
CNF1
(WH)
7
1
1
2
3
CNDC
(PK)
52C
1
3
1
(BK)
21S4
TB3
2
RD
M1
M2
RD
BK
S
TO INDOOR UNIT
OR BRANCH BOX
CONNECTING WIRES
30VDC(Non-polar)
TB7
2
YE
M1
M2
YE
S
FOR CENTRALIZED
CONTROL
30VDC(Non-polar)
POWER SUPPLY
~/N
220-230-240V 50Hz
220V 60Hz
TO BRANCH BOX
SYMBOL
NAME
TB1
Terminal Block <Power Supply/Branch Box>
TB3
Terminal Block <Indoor/Outdoor, Branch
Box/Outdoor Transmission Line>
TB7
Terminal Block
<Centralized Control Transmission Line>
FUSE1,FUSE2 Fuse <T20AL250V>
MC
Motor for Compressor
MF1
Fan Motor
63H
High Pressure Switch
63HS
High Pressure Sensor
63LS
Low Pressure Sensor
SV1
Solenoid Valve Coil <Bypass Valve>
21S4
Solenoid Valve Coil <4-Way Valve>
TH2
Thermistor <Hic Pipe>
TH3
Thermistor <Outdoor Liquid Pipe>
TH4
Thermistor <Compressor>
TH6
Thermistor <Suction Pipe>
TH7
Thermistor <Ambient>
OCH668B
PUMY-SP125VKM(R1).TH
63H
TH7 TH6 TH3 TH4
TH2
63LS
63HS
1
3
1
4
1 2
2
1
1
2
63HS
TH7/6
TH3
TH4
TH2
(WH)
(RD)
(WH)
(WH)
(BK)
1
3
1
3
63LS
63H
(BU)
(YE)
CN2
(RD)
1
TRANS
7
F1
F2
21S4
SV2
SV1
3
1
3
1
3
1
3
1
2
SS
(GN)
(BU)
(GY)
(WH)
SV1
2
TH8
P. B.
1 2
1 2
CN6
CN4
(WH)
(WH)
IC600
W
W
BK
V
MS
V
3~
WH
U
U
RD
MC
7
1
7
CN2
(RD)
TB3B
BK
TB1
RD
L
BU
N
GNYE
RD
B1
FUSE1
BU
B2
FUSE2
SYMBOL
TH8
Thermistor <Heat Sink>
LEV-A, LEV-B Linear Expansion Valve
DCL1, DCL2, DCL3
Reactor
P.B.
Power Circuit Board
U/V/W
Connection Terminal <U/V/W-Phase>
LI
Connection Terminal <L-Phase>
Connection Terminal <N-Phase>
NI
TB1A, TB2A, TB3A,
Connection Terminal <Reactor>
TB1B, TB2B, TB3B
EI, E3, E4
Connection Terminal <Electrical Parts Box>
MULTI.B.
Multi Controller Circuit Board
SW1
Switch <Display Selection>
SW2
Switch <Function Selection>
SW3
Switch <Test Run>
SW4
Switch <Model Selection>
SW5
Switch <Function Selection>
SW6
Switch <Function Selection>
SW7
Switch <Function Selection>
PUMY-SP140VKM(R1).TH
LEV-A
LEV-B
M
M
CN3D
CN3S
CN3N
SWU2 SWU1 SW9
(WH)
(RD)
(BU)
1
3 1
3 1
3
1
5
1
5
CNLVA
CNLVB
(WH)
(RD)
1
5
CN51
(WH)
7
CN4
(WH)
2
1
2
CNS1
CNS2
LED3
CN41
(RD)
(YE)
(WH)
2 1 2 1
CNAC
4
1
(RD)
2
2
2
2
2
CNAC2
CNAC1
(RD)
(WH)
1
3 1
3
2
CNDC
(PK)
1
3
IC500
DS
TB2B
TB1B
TB1A TB2A TB3A
WH RD
RD
WH
BK
1 MODEL SELECTION
DCL1
The black square( )indicates a switch position.
DCL2
MODELS
DCL3
PUMY-SP112VKM
PUMY-SP125VKM
PUMY-SP140VKM
NAME
SYMBOL
SW8
SW9
SWU1
SWU2
CNS1
CNS2
SS
CN3D
CN3S
CN3N
CN51
LED1,LED2
LED3
F1,F2
M-NET P.B. M-NET Power Circuit Board
TB1
27
is the switch position.
SW5
SW6
SW1
SW8
SW2
SW4
SW3
SW7
LED1
LED2
CN102
(WH)
4
1
CN40
(WH)
4
1
4
M-NET P.B.
1
4
CN2
(WH)
TB1
BK
CN1
(WH)
1
5 3
2
LI
NI
BK
BK
BK
SW2
SW4
SW8
ON
ON
ON
OFF
OFF
OFF
5 6
1 2 3 4 5 6
1 2
ON
ON
ON
OFF
OFF
OFF
5 6
1 2 3 4 5 6
1 2
ON
ON
ON
OFF
OFF
OFF
5 6
1 2 3 4 5 6
1 2
NAME
Switch <Model Selection>
Switch <Function Selection>
Switch <Unit Address Selection, ones digit>
Switch <Unit Address Selection, tens digit>
Connector <Indoor/Outdoor, Branch Box/
Outdoor Transmission Line>
Connector <Centralized Control Transmission Line>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
LED <Operation Inspection Display>
LED <Power Supply to Main Microcomputer>
Fuse <T6.3AL250V>
Relay
Connection Terminal <Electrical Parts Box>
SW9
ON
OFF
3 4
ON
OFF
3 4
ON
OFF
3 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents