IDD Processing & Packaging SQUIRE PLUS 2 Operation Manual page 116

2-head washer / filler
Table of Contents

Advertisement

SQUIRE PLUS 2 OPERATIONS MANUAL
2. Ensure you are pressing SCAV to remove excess product at the end of each fill
• Product in the coupler causes near-immediate back pressure and sets off the
IR sensor, stopping the fill before it is complete
Fills Are Stopping
Check for the following, in order:
1. Make sure the Product Pump is running
2. Ensure the Bright Tank maintains 15 psi of Head Pressure
3. Make sure the Product Valve is opening and showing the yellow indicator
• If not – see Wash Reject notes
4. Make sure the Manual Drain Valve is open and the Manual CIP Return Valve is
closed. If both are closed, no CO
equilibrium, unable to complete the fill
5. There may be other issues:
• There may be a drain hose attached to the Drain – See S
under the S
C
UGGESTED
OMPONENTS
• The Coupler may be the problem, Refer to Wash Side, Kegs Are Rejecting
Fill Cycle Rejects
Check for the following, in order:
1. Make sure the solenoid light is
2. If the Valve's yellow indicator is not up, make sure the air is on and that incoming
air is set at 80 psi
3. If the air is good, disconnect hose from the valve and check for air flow:
• If air is not flowing into valve – Manually over-ride the solenoid with a small
flat-bladed screwdriver, by turning clockwise ¼ of a turn.
Air begins flowing – The solenoid is bad and needs replacing
o
Air still does not flow
o
 Check the air supply again
 Check for water in the solenoid. If water is found, use a desiccant
filter and an air dryer to resolve
• If air is flowing into valve – the valve is bad, see Valve Malfunction
4. If Air is good and the Valve is working, check the coupler:
• The Coupler is not working:
Check the Coupler for damage, wear and tear, worn O-Rings (which
o
become misshapen and spread out to block the drain area)
Make sure the handle is working correctly
o
Use a repair kit if possible, or replace the coupler
o
• The Coupler is working:
Check the IR Probe (run the machine and watch the probe. When water
o
runs out of the drain, and the probe remains
Check the IR Probe and it turns off, but there is no water:
o
 Check that the drain valve is open
 Check the air pressure again (from start of this issue)
PROCESS & PACKAGING, INC.
is vented and the keg and hoses reach
2
ECTION
for drain modification information
and the valve indicator is up (see #4, below)
ON
, it is bad
ON
www.iddeas.com
5 – S
,
ERVICES
P
116
125
AGE
OF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents