Label
Settings
U1
Sensor Type
U2
Signal
Offset
U3
Output Signal Offset
U4
Signal Filter
U5
Set Point Dead Band (SP1)
U6
Set Point Dead Band (SP2)
U7
Power Save
U8
Display Stabilizer
L
Set Point Limit
F1
SP2 and U7 Disable
F2
Heat/Cool Switch
F3
Alarm Enable
F4
Unit Display Enable
F5
Temperature Unit
F6
Current Output Enable
This setting tells the DQ15D control what type of sensor it is using.
Value Board
1
5414 or 5416
2
5414 or 5416
3
5447* or 5416
4
5447* or 5416
5
5418* or 5419* Thermocouple
6
5418* or 5419* Thermocouple
7
5418* or 5419* Thermocouple
8
5418* or 5419* Thermocouple
9
5447* or 5416
10
5447* or 5416
11
5447* or 5416
12
5447* or 5416
Note: The 5447 sensor board will also accept 2 wire RTDs. The default sensor type setting is "1" (1000 ohm 2
wire RTD). When using the 5447 sensor board, an "on-board" DIP switch must also be configured, see page 14.
M-34-01-06 3/31/2016

Main Menu Summary

Description
Used to select the type of sensor
Offset value from -9 to +9 applied to reading
Adjusts 4-20 mA output from -9 to +9
Adjustable running average filter on input signals
Value from 1 to 99 applied to SP1
Value from 1 to 99 applied to SP2
Set Point value from 1 to 99, power save mode
Reduces display instability when used in conjunction with U4
High set point limit for SP1`, SP2, power save and alarm
Modifies DQ15D controller to single set point
N/A
Toggle flag to enable the "alarm set point" feature
Toggle flag enabling temperature units to be displayed
Toggle flag to select ºF or ºC
Enable 4-20 mA output
Sensor Type
Sensor Description
2-wire RTD
Platinum RTD, TCR 0.00385 ohm/ohm/ºC
2-wire RTD
Platinum RTD, TCR 0.00392 ohm/ohm/ºC
3-wireV RTD
Platinum RTD, TCR 0.00385 ohm/ohm/ºC
3-wire RTD
Platinum RTD, TCR 0.00392 ohm/ohm/ºC
J-Type Iron-Constantan NIST Monograph 175 REV ITS-90
K-Type Chromel-Alumel NIST Monograph 175 REV ITS-90
T-Type Copper-Constantan NIST Monograph 175 REV ITS-90
R-Type Platinum, 13% Rhodium-Platinum NIST Monograph 175
Voltage
Potential signal (1.0 to 10.0 V)
Current
Current signal (4.00 to 20.00 mA)
Frequency
Pulse train frequency (0 to 200 Hz, counts per second)
Resistance
Pure resistance signal (0 to 1000 ohms)
*Input boards 5418, 5419 and 5447 are no longer available.