Sp2 And U7 Disable (F1); Alarm On/Off Switch (F3); Unit Display Enable (F4); Temperature Units Conversion (F5) - Process Technology DQ15D Instruction Manual

Digital temperature control
Table of Contents

Advertisement

This setting may be either a one (1) or a zero (0), and controls the behavior of the DQ15D by making it per-
form like the single Set Point PROCESS TECHNOLOGY model DE control. When this setting is set to one (1),
it is ON. The SP2 Set Point and the U7 Power Save Set Point are both disabled and will not work.
Not available.
This setting may be a zero (0) or a one (1). When set to zero, the alarm set point is turned off. When set to one,
alarm set point is turned on.
Note: The default value for this setting is zero (0).
This setting may be set to a zero (0) or a one (1). When set to one (1), the DE20 will display either a "C" or an
"F", separated by a decimal point. This indicates that either Celsius or Fahrenheit is being displayed. If the tem-
perature being measured is greater than +999 degrees, the units are not shown because the display is limited
to four positions.
This setting may be set to a zero (0) or a one (1). When set to a zero (0), the temperature is displayed in
degrees Fahrenheit. When set to a one (1), the temperature is displayed in degrees Celsius.
Conversion from F to C does NOT change set point or alarm upper limit values. These must be changed
manually.
Note: The default setting is zero (0).
This setting can be either zero (0), which is OFF, or one (1), which is ON. When ON, it enables the optional
current adder board on the DQ15D. See 4-20 mA Output Option for details on the current output signal.
If the DQ15D is equipped with the optional 4-10 mA output feature, then setting F6 to one (1) turns ON this
feature. F6 must be ON before any calibration can be performed.
The default setting is zero (0). Only active when using the optional 5416 board.
M-34-01-06 3/31/2016
F1, SP2 and U7 Disable
F2, Heating or Cooling Switch
F3, Alarm On/Off Switch
F4, Unit Display Enable Flag
F5, Temperature Units Conversion
F6, Current Output Enable Flag
18