Maintenance / Special Operating Mode Functions - Fujitsu WATERSTAGE 112 Maintenance Document

Waterstage series 3 phase air/water heat pump split system, single service
Hide thumbs Also See for WATERSTAGE 112:
Table of Contents

Advertisement

Heat Pump, Split System, Single Service, 3 phase
6.3.12
Maintenance
Maintenance functions can be used as a preventive
step for periodically monitoring the installation. All
maintenance
functions
activated / deactivated.
Line no.
Programming line
7070
HP interval
7071
HP time since maint
7072
Max starts compr1/hrs run
7073
Cur starts compr1/hrs run
7076
Diff condens max/week
7077
Cur diff condens max/week
7078
Diff condens min/week
7079
Cur diff condens min/week
7090
DHW storage tank interval
7091
DHW stor tank since maint
HP interval :
Defines the maintenance frequency (in months) for
the heat pump.
HP time since maint :
Displays the time (months) elapsed since the last
maintenance. If the value exceeds the "heat pump
interval" setting (Line 7070), the symbol
displayed and a maintenance message will appear in
the Info section:
17: Heat pump maintenance Interval (Priority 6)
This setting can be reset with the associated rights of
access.
Max starts compr1/hrs run :
Defines the maximum number of compressor 1
startups per hour of operation.
Cur starts compr1/hrs run :
The average number of compressor startups per hour
of operation, obtained over a period of 6 weeks.
If the value exceeds the "Comp1 max startups/hr op"
adjusted setting, the symbol
a maintenance message will appear in the Info
section:
8: Too many compressor 1 startups (Priority 9)
This setting can be reset with the associated rights of
access.
Diff condens max/week :
This setting indicates how many times over 7 days
the
maximum
temperature
condenser can be exceeded.
Maintenance Document 1394-1

Maintenance / Special Operating Mode Functions

can
be
individually
will be displayed and
difference
on
The controller automatically generates maintenance
messages if the settings defined are either exceeded
or fail to be reached.
Cur diff condens max/week:
Number
of
difference on the condenser has been exceeded
during a 7-day period. If the value exceeds the setting
"Max cond diff/week" (line 7076), the symbol will be
displayed and a maintenance message will appear in
the Info section:
13: Max cond diff (Priority 3)
will be
This setting can be reset with the associated rights of
access.
Diff condens min/week :
Indicates how many times over 7 days the minimum
temperature difference on the condenser may fail to
be reached.
Cur diff condens min/week (7079):
The number of times the minimum temperature
difference on the condenser has not been reached
over a 7 period. If the value is higher than the setting
"Min cond diff/wk" the symbol
and a maintenance message will appear in the Info
section:
14: Min cond diff (Priority 3)
This setting can be reset with the associated rights of
access.
DHW storage tank interval (7090):
Adjustment of the maintenance frequency (in months)
of the DHW tank.
the
times
the
maximum
will be displayed
temperature
101