Ventilation

The refrigeration unit is ventilated only via
the ventilation grille in the base. Never cover
the ventilation grille or place anything in front of it.
Otherwise the refrigeration unit must work harder,
increasing the power consumption.

Connecting the appliance

Have a technician install and connect the appliance
according to the enclosed installation instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until
the appliance has been installed.
In addition to the statutory national regulations,
observe the connection conditions of the local power
supply companies.
After installing the appliance, wait at least 1 hour until
the appliance starts up. During transportation the oil
in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
"Cleaning the appliance").
6
Electrical connection
9
WARNING:
Risk of electric shock!
9
WARNING:
Only insert the appliance into an earthed, 3-phase
outlet. Never remove the earth phase. Do not use any
adapters.Do not use any extension cables.
9
WARNING:
Incorrect connection of the appliance may result in
death, fire or electric shock. Improper connection of
the protective conductor may result in electric shock.
If you are in doubt as to whether the appliance has
been properly earthed, have it tested by a qualified
electrician or Customer Service technician.
Do not use extension cables or distributors. This
appliance must be connected to a permanently
installed outlet.
The outlet must be in the vicinity of the appliance and
be freely accessible even after the appliance has been
installed.
The appliance complies with protection class I.
Connect it to a correctly installed outlet. Correct
means: with a protective conductor, 110 V – 120 V/
60 Hz alternating current. The outlet must be fused
with a 10 A – 16 A fuse.
The appliance comes with a UL-registered, 3-wire
power cord. The appliance requires a 3-pole outlet.
Please observe the following table with regard to this:
Appliance
Maximum simulta-
neous load
Wine refriger-
2 A
ator
Check on the rating plate whether the indicated
voltage and current type correspond with the values of
your power supply. The location of the rating plate can
be found in the Customer Service chapter.
9
WARNING:
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are
used for photovoltaic systems which are connected
directly to the national grid. Sine-controlled inverters
must be used for isolated applications (e.g. on ships
or in mountain lodges) which are not connected
directly to the national grid.