Functional description and configuration using Web based Management
7.6 The X200 menu
Figure 7-17
Enable Link Up Monitoring
Select the check boxes of the ports whose connection status you want to monitor. If link
monitoring is activated, an error is signaled when there is a valid link at this port because, for
example, the cable should not be plugged in.
An error/fault can be signaled in the following ways depending on the configuration of the
SCALANCE X-200RNA: Signaling contact, fault LED, SNMP trap, entry in the log table and
the syslog.
66
Fault Mask Link Up Monitoring
SCALANCE X204RNA SCALANCE X204RNA EEC
Operating Instructions, , C79000-G8976-C294-03