Table 5-1 Maximum permissible continuous output current @ 40 °C (104 °F) ambient
Maximum permissible continuous output
Nominal
current (A) for the following switching
Model
rating
2
kW
hp
kHz
200 V
05200250
7.5
10
06200330
11
15
06200440
15
20
400 V
05400270
15
20
05400300
15
20
06400350
18.5
25
06400420
22
30
06400470
30
40
575 V
05500030
2.2
3.0
05500040
4.0
5.0
05500069
5.5
7.5
06500100
7.5
10
06500150
11
15
06500190
15
20
06500230
18.5
25
06500290
22
30
06500350
30
40
Unidrive M Frame 5 to 6 Power Installation Guide
Issue Number: 3
Normal Duty
frequencies
3
4
6
8
kHz
kHz
kHz
kHz
30
50
58
53
30
25.8
22.2
31
30.7
26.4
38
48
41
63
57
48
41
3.9
6.1
10
12
17
22
27
26.2
34
31
26.2
43
39.6
31
26.2
Maximum permissible continuous output
Nominal
current (A) for the following switching
rating
12
16
2
kW
hp
kHz
kHz
kHz
27.6
23.7
5.5
7.5
42.3
24.5
7.5
10
42.3
32.5
11
15
17.1
13.5
11
20
27
18.3
14.1
15
20
31
24.3
15
25
31
24.5
18.5
30
31
24.5
22
30
47
1.5
2.0
2.2
3.0
4.0
5.0
5.5
7.5
14.8
7.5
10
20.5
15
11
15
20
16
15
20
20
16.8
18.5
25
20
16.8
22
30
35
Heavy Duty
frequencies
3
4
6
8
kHz
kHz
kHz
kHz
25
24.8
33.0
44.0
40
25.4
23.7
20.3
17.6
30
27.9
24
21
35
30
42
35
30
46
42
35
30
3.0
4.0
6.9
10
15
19
23
20
29
23.8
20
34
29.8
23.8
20
12
16
kHz
kHz
21.5
18.8
32
27
33
27.3
13.8
11.1
14.9
12.2
23
18.5
23
18.5
23
18.5
11.6
15.4
11.6
15.4
12.8
15.4
12.8
15.4
13
33