RF300 system planning
4.1 Fundamentals of application planning
4.1.9

Calculation example (RS422)

A transport system moves pallets with transponders at a maximum velocity of V
(dynamic mode). The following RFID components were selected:
● ASM 475 communication module
● RF310R reader with RS422 interface
● Transponder RF340T
Task
a) The designer of the plant is to be given mechanical specifications.
b) The programmer should be given the maximum number of bytes in dynamic mode.
Refer to the tables in the "Field data of transponders and readers" section for the technical
data.
Determine tolerance of pallet transport height
Figure 4-6
42
Tolerance of pallet transport height
Tag
SIMATIC RF300
System Manual, 01/2009, A5E01642529-03
= 1.0 m/s