Readers
5.2 SIMATIC RF310R with RS422 interface
5.2.4

Display elements of the RF310R reader with RS422 interface

Color
Green
Yellow
Flashing red
1)
5.2.5

Ensuring reliable data exchange

The "center point" of the transponder must be situated within the transmission window.
5.2.6

Metal-free area

The RF310R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 5-4
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
100
Meaning
Flashing
Operating voltage present, reader not initialized or antenna switched off
Permanentl
Operating voltage present, reader initialized and antenna switched on
y on
Transponder present
1)
Error has occurred, the type of flashing corresponds to the error code in the
table in Section "Error codes". The optical error display is only reset if the
corresponding reset parameter ("option_1", see FC45 / FB45 documentation,
Section "Input parameters") is set.
Only in the "with presence" mode.
Metal-free area for RF310R
SIMATIC RF300
System Manual, 01/2009, A5E01642529-03