7
SCANNING OPERATION
The
IC-725
is
equipped with
three separate scan functions
which
provide
tremendous
scanning
versatility
at
the
touch
of
a
few
switches.
7-1
SCAN TYPES
SCAN
NAME
FUNCTION
PROGRAMMED
SCAN
Repeatedly
scans
between
two
user-
programmed
scan edges
(MEMO
25
and
26).
MEMORY
SCAN
Repeatedly
scans
all
memory
chan-
nels.
SELECTED
MODE MEMORY
SCAN
Repeatedly
scans
memory
channels
with
the
same
selected
operating
mode.
7-2
PROGRAMMED SCAN
Scan
Scan edge
A
or
B
Scan edge
B
or
A
Jump
1
)
Program
the high
and low
frequency
edges of the desired
scanning range
into
MEMO
25 and
26.
See
p.
22
for
programming
the
memory
channels.
• Either
channel can have the
higher or
lower frequency
stored.
2)
Push
the
[VFO]
switch to
select
VFO
mode.
3) Select
LSB,
USB,
CW,
AM
or
FM
mode.
4)
Adjust the
[SQL]
control to the threshold
point.
5)
Push
the
[FUNC]
switch then
push
the
[VFO]
switch.
•
The
scan begins
from
the lower
limit
of the
range.
•
The
scan stops
when
a
receive
signal
opens
the squelch.
•
The
scan
resumes
after
the
signal
disappears.
6)
Push the
[VFO]
switch again to stop the
scan.
•
The
following switches
and
controls
also
stop the
scan:
[PTT]
[TRANSMIT] [MEMO] [MW]
MAIN
DIAL
7-3
MEMORY
SCAN
1)
Program
the
desired frequencies into
memory
channels.
See
p.
22
for
programming
memory
channels.
2)
Push
the
[MEMO]
switch to
select
the
MEMORY
mode.
3)
Adjust the
[SQL]
control to the threshold
point.
4)
Push
the
[FUNC]
switch
then push
the
[MEMO]
switch.
•
The
scan
begins.
•
The
scan stops
when
a
receive
signal
opens
the
squelch.
•
The
scan
resumes
after
the
signal
disappears.
5)
Push
the
[MEMO]
switch again to stop the
scan.
•
The
following switches
and
controls
also
stop the
scan:
[PTT]
[TRANSMIT]
[VFO] [MW]
MAIN
DIAL
7-4
SELECTED
MODE MEMORY
SCAN
Men
1
Mch
2
^CjsB^y-
Mch
3
-*<^CW^)
Mch
4
Mch
26
Mch
7
Mch
6
./Mch
5
1
)
Program
the
desired frequencies into
memory
channels.
See
p.
22
for
programming
memory
channels.
2)
Push
the
[MEMO]
switch to
select
MEMORY
mode.
3)
Adjust the
[SQL]
control to the threshold point.
4) Select
LSB,
USB, CW,
AM
or
FM
modes.
5)
Push
the
[LOCK]
switch
IN.
6)
Push
the
[FUNC]
switch
then push
the
[MEMO]
switch.
•
The
scan
begins.
•
The
scan stops
when
a
receive
signal
opens
the
squelch.
•
The
scan
resumes
after
the
signal
disappears.
7)
Push
the
[MEMO]
switch again to stop the
scan.
•
The
following switches
and
controls
also
stop the
scan:
[PTT]
[TRANSMIT]
[VFO] [MW]
MAIN
DIAL
7-5
SUPPLEMENTAL SCAN
SETTINGS
(1)
SCAN SPEED
Scan
speed
in
the IC-725
is
set
for
fast
speed
at
the
factory.
See
p.
28
for
converting
to
a
slower scan speed.
(2)
SCAN CLEAR
The
scan function
can be automatically
cleared
when
the
transceiver
receives
a
signal.
See
p.
28
for
setting
the
transceiver
in
the scan
clear
condition.
Need help?
Do you have a question about the IC-725 and is the answer not in the manual?
Questions and answers