Technical Specifications; Troubleshooting - Mighty Mule VEHICLE SENSOR Installation Manual

Hide thumbs Also See for VEHICLE SENSOR:
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS:

Power supply: 8-26 Vac/dc.
Current consumption: 1.5 mA typical.
Relay rating: Latching relay.
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Relay Trip Time: 2 seconds.
Operating Temperature: -25°F (-14°C) to 125°F (69°C).
Dimensions: 1-3/4" (44.5 mm) diameter x 16.5" (42 cm) long.
Adjustable range: 3 -12 feet typical installation.
Very low power consumption, ideal for battery application.

Troubleshooting:

If the SENSOR is not working:
1. Make sure the Range Adjustment is set at maximum range.
2. Disconnect the power (battery) to the SENSOR.
3. Reconnect the power to the SENSOR and make sure that no metal object or vehicle is moving
around the SENSOR for 60 seconds while it is calibrating.
4. Test the SENSOR to verify that it is working properly.
5. Check that push/pull DIP switches on Control Board are set correctly.
Make sure all connections are correct.
1 Amp 30 Vdc, 0.5 Amp 125 Vac
30 Watt, 62.5 V A
110 Vdc, 125 Vac
1 Amp
8

Advertisement

Table of Contents
loading

Table of Contents