▶Open Duration (0.1 sec unit)
Designates the time the door is opened and closed again when authentication is
successful. As it is set to 0.1 second per unit, a value of 30 is required to set it to 3
seconds. Strike type refers to the time the door is opened and closed again when
authentication is complete.
▶Warn Door Open (Second Unit)
This function enables the terminal to check the time the door opens, and generate a
warning sound once it exceeds the preset time (min. 5 sec~ max. 30 sec).
When set to '00', warning doesn't sound at all. If set between 01~04, it only starts
sounding after 5 seconds have elapsed.
The warning sound is also generated in cases where the door is unexpectedly not
closed within the preset time; although the door should be closed. This warning allows
proper action to be taken for the door to be closed.
To use this function, the lock must be the one that enables the monitoring of the door
door status, and the monitoring pin of the lock should be connected to the terminal.
In addition, such settings are enabled only when the aforementioned Door Monitor is
set to '4. Normal Open' or '5. Normal Close'.
The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use
the [F4 (←)] key to cancel input during setting.

3.7.4. Wiegand

Select [ENT~]  [5. Terminal]  [4. Wiegand] in the initial screen ◆, and the following
screen appears:
This menu configures the Wiegand Output.
Used only when a separate controller, operating with Wiegand input, is mounted. Upon
successful authentication, it transmits the data to the terminal's Wiegand port in the
following form:
2.None
This is the normal case. Wiegand Output is not used.
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro,
Songpa-gu, Seoul, 05836, Republic of Korea
TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr
http://www.unioncomm.co.kr
▶Initial setting: Identical with the screen on the left
54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac-5100

Table of Contents