Hide thumbs Also See for AC-5000:
Table of Contents

Advertisement

Quick Links

AC-5000, 5100 User Guide
Version eng-2.07
Copyright 2000 By Union Community Co., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Union Community AC-5000

  • Page 1 AC-5000, 5100 User Guide Version eng-2.07 Copyright 2000 By Union Community Co., LTD.
  • Page 2: Revison History

    AC-5000 / 5100 User Guide <Revison History> Version Date Description Firmware Version 2.00 2015-07-13 Initial Release 30.62.00-000.00 2.01 2015-10-19 1.2. Terminal Description 30.62.00-000.01 2.1. Features 2.3. Specification 3.2. Menu Configuration 2.02 2015-11-18 3.6.1. System Setting 30.62.00-000.02 3.6.4. Language 2.03 2016-01-07 3.6.2.
  • Page 3 AC-5000 / 5100 User Guide <Glossary>  AC5000: Terminals not supported by Camera  AC5100: Terminals supported by both Camera  Admin, Administrator - A user who can enter the terminal menu mode. They are authorized to register/modify/delete terminal users and alter the operating environment by changing the settings.
  • Page 4: Table Of Contents

    AC-5000 / 5100 User Guide Table of Contents <Revison History> ....................2 1.2. Terminal Description ................... 2 2.1. Features ....................... 2 2.3. Specification ....................2 3.2. Menu Configuration ..................2 3.6.1. System Setting ..................2 3.6.4. Language ....................2 3.6.2. Authentication ..................2 2.1.
  • Page 5: Ac-5000 / 5100 User Guide

    AC-5000 / 5100 User Guide 3.3.4. Delete All .................... 35 3.4. Network ...................... 35 3.4.1. IP ......................36 3.4.2. Server IP ..................... 36 3.4.2.1. Server IP settings ................37 3.4.2.2. DDNS ....................37 3.4.3. Terminal ID ..................38 3.5. Application ....................39 3.5.1.
  • Page 6: Before Use

    - If the above cautions are ignored, it may result in property damage or human injury. ※ Under no circumstances will Union Community be responsible for accidents or damages caused by inappropriate use of the product and neglect of the precautions stated in the user guide UNIONCOMMUNITY Co., Ltd.
  • Page 7: Terminal Description

    AC-5000 / 5100 User Guide 1.2. Terminal Description State Display LED Camera (AC5100 only) Fingerprint Sensor Touch Key Normally, the figures are invisible as the LED is off. LED turns on and the figures illuminate when the user lightly touches this area Card Input Area UNIONCOMMUNITY Co., Ltd.
  • Page 8: Screen Description (During Operation)

    AC-5000 / 5100 User Guide 1.3. Screen Description (During Operation) ① Fire Detection ②Warning of Terminal Disassembly, etc. Access Mode ③Door State ④Connection with Server Current Time 1.3.1. Icons Shown During Operation None : Normal ① Fire Detection : State when fire is detected by a fire sensor (subject to the appropriate fire sensor connection).
  • Page 9 AC-5000 / 5100 User Guide 1.3.2. Message Shown During Operation - Initial screen of AC5000. - When authentication is successful. - When authentication has failed. - When any unregistered user ID is input. - When fingerprint authentication is attempted where the server is not connected or there is no registered fingerprint in the terminal.
  • Page 10 AC-5000 / 5100 User Guide - If a user made two or more attempts at the same meal time zone (if being used for cafeteria operation). - If there is no response from the server when attempting authentication to the server.
  • Page 11 AC-5000 / 5100 User Guide - Status waiting for password input from the user. - Status waiting for fingerprint input from the user. - Status waiting for card input from the user. - During fingerprint card authentication, it shows the status when the card reads fingerprint data.
  • Page 12: Led Signal Shown During Operation

    AC-5000 / 5100 User Guide 1.4. LED Signal Shown During Operation On: Normal ● Flickering: When the lid is open, or there is any communication error in the connection with the LC010. On: Door Open ● Door Green Off: Door Closed...
  • Page 13: Buzzer Sounds Used During Operation

    AC-5000 / 5100 User Guide When authentication is You are authorized. successful When authentication Please try again has failed 1.7. Buzzer Sounds Used During Operation Sound that is generated When the key is pressed or card is read; when a key is...
  • Page 14 AC-5000 / 5100 User Guide Precautions related to the user’s fingerprint status:  Depending on the fingerprint status, the user may not use fingerprint or suffer inconvenience from its use.  This product is a fingerprint recognition system. Any fingerprint that is damaged or thin may not be used.
  • Page 15: Product Introduction

    AC-5000 / 5100 User Guide 2. Product Introduction 2.1. Features  IP65 Environmental standard is designed for Outdoor installation  Slim and sophisticated design - Easy to install as it is designed as a vertical type; Slim and elegant design using Color LCD and Touch Keys ...
  • Page 16 AC-5000 / 5100 User Guide Fingerprint Registration Fingerprint Authentication Password Registration Password Authentication FP or PW Fingerprint and Password Registration Password Authentication when Fingerprint Authentication fails FP & PW Fingerprint and Password Registration Fingerprint Authentication and then Password Authentication Card...
  • Page 17: Configuration

    AC-5000 / 5100 User Guide 2.2. Configuration 2.2.1. Standalone (Access) DC12V Adapter Electromagnetic Lock (Lock+, Lock-, Monitor) 2.2.2. Connect with PC SERVER (Access, Time & Attendance, Cafeteria) TCP/IP TCP/IP Fingerprint Authentication Server (Fixed IP) UDB Server TCP/IP Database (MDB or MSSQL)
  • Page 18: Specification

    AC-5000 / 5100 User Guide 2.3. Specification Category SPEC REMARK 32Bit RISC CPU(528MHz) Environmental IP65 2.8” TFT Color (320*240) Touch Key 15key (0~9, F1~F4, Enter) 32M SDRAM 20,002 User 20,002 Finger 32M NOR FLASH MEMORY 1:N 15000 User 1:1 5002 User...
  • Page 19 AC-5000 / 5100 User Guide 125KHz RF Card Reader 13.56MHz Smart (1 Sam Socket) Option HID Card SIZE 88.0mm * 175.0mm * 43.4mm UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr...
  • Page 20: Environment Settings

    AC-5000 / 5100 User Guide 3. Environment Settings 3.1. To be checked before environment settings. 3.1.1. Enter the Menu. Press the [ENT] key and hold for two seconds or longer. The user can access to the screen for menu selection, as follows: <Figure 3-1>...
  • Page 21: Modify Set Values

    AC-5000 / 5100 User Guide This is the way to access the menu if fingerprint authentication is impossible, or because the user forgot the admin password, or lost the card registered on the terminal, or there is no Admin. ① Remove the bracket on the rear of the terminal to open the lid.
  • Page 22 AC-5000 / 5100 User Guide ▶ ① Input Box For items where the value is directly input, such as the ‘1:1 Level’, users must delete the existing value using the [F4 (←)] key when the applicable item is highlighted. Then input the new value using the [0] ~ [9] keys.
  • Page 23: Move To Page

    AC-5000 / 5100 User Guide Press the [F4 (←)] key to cancel, while setting, and move back to the parent menu. When the highlight is located at the input box the [F4 (←)] key functions as a [DEL] key, which deletes figures one by one. Press the [F4 (←)] key for two seconds, or longer, to cancel input and exit to the parent menu.
  • Page 24: Save Environment Settings

    AC-5000 / 5100 User Guide 3.1.5. Save Environment Settings Press the [F4 (←)] key in the main menu screen of <Figure 3-1> to save the changed settings, and the following screen appears: <Figure 3-7> Select [1. Yes] to save the new configuration or [2. No] to cancel it. Then press the [ENT] key.
  • Page 25: Menu Configuration

    AC-5000 / 5100 User Guide 3.2. Menu Configuration 1. User 1. Add 2. Delete 3. Modify 4. Delete All 2. Network 1. IP 1. Static IP / 2. DHCP ▶IP Address ▶Subnet Mask ▶Gateway 2. Server IP 1. Static IP 2.
  • Page 26 AC-5000 / 5100 User Guide 4. Extended Key ▶ Extended Key ▶of Extended Key 5. Display ▶ Background ▶ Screensaver ▶ Clock position 6.RS485 ID Setting ▶RS485 ID Setting UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr...
  • Page 27 AC-5000 / 5100 User Guide 4. System 1. System Setting ▶User ID Length ▶Display Option ▶Threat fingerprint alarm ▶Alarm time (sec) 2. Authentication ▶User Group IP ▶Enable 1:N ▶Card Only ▶Template On Card ▶Verify Multi-FP ▶Blocking Time (sec.) ▶NetErrTime(Sec) 3. Fingerprint ▶1:1 Level [1~9]...
  • Page 28: User

    AC-5000 / 5100 User Guide 3. Door ▶Lock Type ▶DM1 ▶DM2 ▶Open Duration ▶Warn Door Open 4. Wiegand □Bypass ▶Wiegand Out ▶Site Code 5. Card Reader ▶Card Format ▶Read Card NO. ▶Dummy Mode 6. External Device ▶Printer ▶Lock Controller ▶Connection Device Setting □Mode...
  • Page 29: Add

    AC-5000 / 5100 User Guide 3.3. 1. Add ◆ Select [ENT~]  [1. User]  [1. Add] ◆ in the basic screen, and the following screen appears: Input the user ID to be registered and press the [ENT] key. Automatically shows the ID to be registered on the screen, so the user can easily perform registration.
  • Page 30 AC-5000 / 5100 User Guide Press the [F4 (←)] key to delete the existing value, enter the authentication method you want to use among the authentication methods shown on the screen, and press the [ENT] key. If you select [AND] mode, authentication will proceed normally with the authentication method.
  • Page 31 AC-5000 / 5100 User Guide If repeated failure is observed after 2~3 attempts when using the correct fingerprint registration method, the user is advised to use password or card. 3.3.1.3. Card Register When registration screen appears, put the card on it.
  • Page 32 AC-5000 / 5100 User Guide ▶’1:1 Level’ (Initial setting: ‘0’) Is the item that determines the authentication level for each registered user. By modifying this value, it is possible to determine the authentication level per registered user. When set to ‘0’, it conducts authentication using the 1:1 authentication level of the terminal.
  • Page 33: Delete

    AC-5000 / 5100 User Guide In the case of [4. PW Register] When the user inputs a different number during password confirmation. In the case of [3. Card Register] When the user tried to register a card that has already been registered.
  • Page 34: Modify

    AC-5000 / 5100 User Guide Input the user ID to be deleted, and then press the [ENT] key. When inputting an unregistered ID, a failure message will appear. When inputting a registered ID, a success message will appear. Deleting from the terminal doesn’t mean deletion from the server. Therefore, it is necessary to delete from the server to make the deletion complete.
  • Page 35: Delete All

    AC-5000 / 5100 User Guide Press the [ENT] key after inputting the user ID to be changed. When inputting an unregistered ID, a failure message will appear. When inputting a registered ID, the following screen appears: The icons on the left are described with their respective meanings on the right.
  • Page 36: Server Ip

    AC-5000 / 5100 User Guide Press the applicable key that represents the item to be changed. 3.4.1. IP Select ◆ [ENT~]  [2. Network]  [1. IP] in the initial screen ◆, and the following screen appears: When changing IP, delete the existing values using [F4 (←)] and then input the new values.
  • Page 37: Server Ip Settings

    AC-5000 / 5100 User Guide Select server IP type for server IP setting. 1. Static IP: If you know the server IP and port number 2. DDNS: When connecting the server by DDNS After selecting the type, press [ENT~] key to enter detailed information. To cancel input, press [F4 (←) ~] key to exit to upper menu.
  • Page 38: Terminal Id

    AC-5000 / 5100 User Guide Set DDNS ID, DDNS IP and server port. DDNS ID can be input from 9 digits 1 to 999999999 can be input. The default value of DDNS IP is 210.116.104.058, and enter the IP of DDNS server to be connected.
  • Page 39: Application

    AC-5000 / 5100 User Guide Authentication is made by the terminal, even if the server is connected, and authentication result transferred to the server on a real-time basis. Terminal/Server 3. Server Only However, authentication is made by the server when the input user ID or card is not registered in the terminal (it doesn’t attempt server...
  • Page 40: Time Schedule

    AC-5000 / 5100 User Guide 3.5.2. Time Schedule 3.5.2.1. Setting to Access Control / Time & Attendance Select ◆ [ENT~]  [3. Application]  [2. Time Schedule] in the initial screen ◆, and the following screen appears: ▶ Initial setting: Identical with the screen on the left.
  • Page 41: Function Key

    AC-5000 / 5100 User Guide 3.5.2.2. Setting to Cafeteria ▶ Initial setting: Identical with the screen on the left. The user can set the time period by meal types; otherwise, set to ‘00:00-00:00’. ▶ NO Limit Clear the check box ( ), and each user is allowed one authentication by meal only.
  • Page 42 AC-5000 / 5100 User Guide ▶Initial setting: Identical with the screen on the left To use the Extended Key, press the [1] key and then check ‘1. Extended Key’. The number of extended keys can be set within a range of 1~40.
  • Page 43: Display

    AC-5000 / 5100 User Guide 3.5.5. Display Select ◆ [ENT~]  [3. Application]  [5. Display] on the initial screen ◆, and the following screen appears: ▶Initial setting: Identical with the screen on the left ▶Background image You can change the background image shown on the initial screen by pressing the [1] and [2] keys.
  • Page 44: System Setting

    AC-5000 / 5100 User Guide Press the applicable key representing the item to be changed. 3.6.1. System Setting Select ◆ [ENT~]  [4. System]  [1. System Setting] in the initial screen ◆, and the following screen appears: ▶ Initial setting: Identical with the screen on the left ▶...
  • Page 45: Authentication

    AC-5000 / 5100 User Guide 3.6.2. Authentication Select ◆ [ENT~] ([4. System] [2. Authentication]) in the initial screen ◆, and the following screen appears: ▶ Initial setting: Identical with the screen on the left ▶ User Group ID The method of authentication where the initial digit of an ID relates to a group. It completes 1:N authentication faster when more than 5,000 users are registered.
  • Page 46: Fingerprint

    AC-5000 / 5100 User Guide ▶ Verify Multi-FP If checked ( ), this function has all the registered fingerprints to be authenticated after the user inputs ID (or Card). When this item is set to checked, the user must, without fail, input user ID or card. In this case, Enable 1:N is automatically changed to unchecked ( This function is used for strict access control to special zones.
  • Page 47: Language

    AC-5000 / 5100 User Guide authentication level of the relevant user is applied for the user whose 1:1 authentication level is not set to ‘0’ (using the authentication level of the terminal). ▶1:N Level Authentication level used for 1:N Fingerprint Authentication. In case of 1:N authentication, the authentication level by users is not set and therefore always based on the authentication level of the terminal.
  • Page 48: Date Time

    AC-5000 / 5100 User Guide nature of fonts, some screens may not be displayed as all the languages. 3.6.5. Date Time Select ◆ [ENT~]  [4. System]  [5. Date Time] in the initial screen ◆, and the following screen appears: ▶Initial setting: Identical with the screen on the left.
  • Page 49 AC-5000 / 5100 User Guide Press the following keys: [1] key to initialize the configuration. [2] key to delete all users. [3] key to initialize the authentication record. and [4] key to initialize the terminal. 3.6.6.1. Init Config Select ◆ [ENT~]  [4. System]  [6. Database]  [1. Init Config] in the initial screen ◆, and the following screen appears:...
  • Page 50 AC-5000 / 5100 User Guide When deletion is successfully completed, it proceeds to the parent menu accompanied by the success buzzer sound. 3.6.6.3. Clear Log Data Select ◆ [ENT~]  [4. System]  [6. Database]  [3. Clear Log Data] in the initial screen ◆, and the following screen appears:...
  • Page 51: Terminal

    AC-5000 / 5100 User Guide 3.7. Terminal Selecting ‘5. Terminal’ in the main menu causes the following screen to appear: Press the key corresponding to the item you want to change Press [F2] on the keypad to move to the next page.
  • Page 52: Volume Control

    AC-5000 / 5100 User Guide ▶KeyLed ON If checked ( ), Key LED is always turned ON so the Touch Keys are visible. ▶ Use of the user voices, Use of user-defined messages Based on need/preference, you can download a voice from a Wav file (16bit/8KHz) to change the voice output when authentication is successful or has failed.
  • Page 53: Door

    AC-5000 / 5100 User Guide 3.7.3. Door Select ◆ [ENT~]  [5. Terminal]  [3. Door] in the initial screen ◆, and the following screen appears: ▶Initial setting: Identical with the screen on the left. ▶Lock Type Set to ‘1’ when strike type or automatic door is connected to the terminal, or ‘2’ when motorized lock is connected to the terminal.
  • Page 54: Wiegand

    AC-5000 / 5100 User Guide ▶Open Duration (0.1 sec unit) Designates the time the door is opened and closed again when authentication is successful. As it is set to 0.1 second per unit, a value of 30 is required to set it to 3 seconds.
  • Page 55: Card Reader

    AC-5000 / 5100 User Guide 3.26bit Transmits “Site code[1byte] + user ID[2byte]”, so the user ID is set to 4 digits or less. Example: For SiteCode:045(2Dh), UID:6543(198Fh), is transmitted as ‘1 00101101 0001 1001 10001111 0’ 4.34bit Transmits “Site code[1byte] + user ID[3byte]” so the user ID is set to 7 digits or less.
  • Page 56: External Device

    AC-5000 / 5100 User Guide Hexadecimal 0801161DD6 10-digit hexadecimal number number Decimal Last 4byte to be expressed in a 10-digit decimal 0018226646 number number (01161DD6h) Decimal 02207638 Same as ‘1. Default’ number 35 Displays last 3bytes as the 6-digit hexadecimal 5.
  • Page 57 AC-5000 / 5100 User Guide ▶Printer To connect a Slave Reader which uses a card or a fingerprint as a secondary authentication device. If you would like a Wiegand card reader to be connected, set ‘7’ while SR100 should be ‘8’. If authentication occurred at the Slave Reader, ‘Dummy Reader’...
  • Page 58: Information

    AC-5000 / 5100 User Guide 3.8. Information Select ‘6. Information’ in the main menu and the following screen appears: Menu to view the terminal settings. Press; [1] key to view various terminal configurations. [2] key to view network configuration, such as IP.
  • Page 59: Database Info

    AC-5000 / 5100 User Guide 3.8.3. Database Info Select ◆ [ENT~]  [6. Information]  [3. Database Info] in the initial screen ◆ - Registered User: Number of registered users (including administrator). - Registered Admin: Number of registered administrators. - Max User: Maximum number of users that can be registered.
  • Page 60: Downloading User's File

    AC-5000 / 5100 User Guide Downloading User’s File 3.9. This function allows the user to change background image or voice message. User files can be downloaded from UNIS server program. 3.9.1. Change Background Image When selecting ‘Download customized file’ in the UNIS program, the following screen appears: Designate the file as ‘Background image file (.jpg)’, select the image file (.jpg), and click...
  • Page 61: Change User Text

    AC-5000 / 5100 User Guide The file name can be up to 15 characters, including the extension name, with the Wav file in 8KHz 16-bit mono form only. If any data in a different format is downloaded, the transmission result will be displayed as a version error.
  • Page 62: How To Use The Terminal

    AC-5000 / 5100 User Guide 4. How to use the Terminal 4.1. Change of Authentication Mode Touch by Hand Press the Desired Mode Key < Figure 4-1> Normally it’s not visible, but when the user touches their hand on the card input area - as shown in the Figure at the left –...
  • Page 63: Id Input

    AC-5000 / 5100 User Guide 4.2. ID input Normally it’s not visible, but as shown in Figure <4-1>, when the user touches their hand on the card input area, the LED’s are powered ON and the keypad appears. In this case, ID input screen appears when the user inputs their ID.
  • Page 64: Password Authentication

    AC-5000 / 5100 User Guide 4.3.3. Password Authentication  Press the [ENT] key after inputting ID, and the screen for password input appears. When a wrong number is input, delete it using the [F4 (←)] key. Input the password and press the [ENT] key.
  • Page 65: Fcc Information

    AC-5000 / 5100 User Guide FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation.

This manual is also suitable for: