No adapter should be used with plug. If
plug does not fit available receptacle, or if
machine must be reconnected for use on a
different type of circuit, reconnection must
be performed by an electrician or qualified
service personnel, and it must comply with
all local codes and ordinances.
G0796 Circuit Requirements
This machine is prewired to operate on a power
supply circuit that has a verified ground and meets
the following requirements:
Nominal Voltage ......... 208V, 220V, 230V, 240V
Cycle ..........................................................60 Hz
Phase .................................................... 1-Phase
Power Supply Circuit ......................... 20 Amps
Plug/Receptacle ............................. NEMA 6-20
Cord ........"S"-Type, 3-Wire, 12 AWG, 300 VAC
The power cord and plug used on this machine
must have an equipment-grounding wire and
grounding prong. The plug must only be inserted
into a matching receptacle (outlet) that is prop-
erly installed and grounded in accordance with all
local codes and ordinances (see figure below).
GROUNDED
6-20 RECEPTACLE
Current Carrying Prongs
6-20 PLUG
Grounding Prong
Figure 6. Typical 6-20 plug and receptacle.
Model G0796/G0797 (Mfd. Since 1/18)
G0797 Circuit Requirements
This machine is prewired to operate on a power
supply circuit that has a verified ground and meets
the following requirements:
Nominal Voltage ......... 208V, 220V, 230V, 240V
Cycle ..........................................................60 Hz
Phase .................................................... 3-Phase
Power Supply Circuit ......................... 15 Amps
Plug/Receptacle ............................NEMA 15-15
Cord ........"S"-Type, 4-Wire, 14 AWG, 300 VAC
The power cord and plug used on this machine
must have an equipment-grounding wire and
grounding prong. The plug must only be inserted
into a matching receptacle (outlet) that is prop-
erly installed and grounded in accordance with all
local codes and ordinances (see figure below).
GROUNDED
15-15 RECEPTACLE
15-15 PLUG
Grounding Prong
Figure 7. Typical 15-15 plug and receptacle.

Extension Cords

We do not recommend using an extension cord
with this machine. If you must use an extension
cord, only use it if absolutely necessary and only
on a temporary basis.
Extension cords cause voltage drop, which can
damage electrical components and shorten motor
life. Voltage drop increases as the extension cord
size gets longer and the gauge size gets smaller
(higher gauge numbers indicate smaller sizes).
Any extension cord used with this machine must
be in good condition and contain a ground wire
and matching plug/receptacle. Additionally, it must
meet the following size requirements:
Minimum Gauge Size (G0796) ............12 AWG
Minimum Gauge Size (G0797) .............14 AWG
Maximum Length (Shorter is Better).......50 ft.
Current
Carrying
Prongs
-17-