Download Print this page

Table Of Contents - GE Druck DPI 610 User Manual

Portable pressure calibrator aeronautical version
Hide thumbs Also See for Druck DPI 610:

Advertisement

Safe working pressure
Ranges
Altitude
Airspeed
Precision
over the airspeed range:
200 knots
400 knots
over the altitude range:
sea level
10,000ft
30,000ft
Precision includes linearity, hysteresis and repeatability, 12 months measurement stability
Temperature Effects
±0.004% of reading/°C (averaged over -10° to +40°C w.r.t. 20°C)
±0.002% of reading/°F (averaged over +14° to 104°F w.r.t. 68°F)
Power supply
Batteries
Rechargeable NiCad battery pack (20 hours nominal use) supplied with charger/
adaptor, supplies power to instrument while charging batteries.
Environment
Operating Temperature:
Calibrated Temperature:
Sealing
Physical
Size:
Weight:
For further general specification and functionality details refer to the standard DPI
610/615 Series Portable Calibrator data sheet.
K0237 Issue No. 2
Specification
6 x 1.5 V C cells, alkaline (up to 60 hours nominal use at 20°C)
Contents
-10°C to 50°C (+14°F to 122°F)
-10°C to 40°C (+14°F to 104°F)
Sealed to IP54 (NEMA 4)
300 x 170 x 140 mm (11.8" x 6.7" x 5.5")
3 kg (6.6lb)
ii
2 x full-scale
-3000 to 50,000ft
0 to 600 knots
±3 knots
±0.7 knots
±14 ft
±18 ft
±36 ft
1
2
2
3
3
6
8
10

Hide quick links:

Advertisement

loading