Care And Maintenance; Troubleshooting - Utilitech 7115-01 Instructions Manual

Easy fit install ventilation fan
Table of Contents

Advertisement

Available languages

Available languages

EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS
9.
Pinch mounting springs (9.1) on grille (B) and insert
into narrow rectangular slots (9.2) inside the fan (A).
Push grille (B) up toward ceiling.
Turn on electricity at breaker box after finishing
installation.

CARE AND MAINTENANCE

WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding.
Routine maintenance should be done at least once a year.
• Wash grille with mild soap and water, dry with a cloth.
• Remove excess dirt and dust from the fan housing with a vacuum cleaner.
• Do not use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse resin parts in water over 140º F.

TROUBLESHOOTING

PROBLEM
The fan seems
louder than it should
POSSIBLE CAUSE
CFM too great
Damper not working properly or
damaged
Bend in duct too close to fan discharge
Fan discharge reduced to fit smaller
duct
Fan body not securely attached
9
9.1
8.1
B
CORRECTIVE ACTION
Be sure the CFM rating on the fan
matches the size of your room
Check damper to ensure it is opening
and closing properly. If the damper
has become damaged, please call
Customer Service
Be sure you do not have any sharp
bends in duct closer than 18 in. to the
fan discharge
Use recommended size ducting to
reduce fan noise
Be sure the fan is securely attached
to your ceiling joists
11
9.2
8.2
A
9.1
8.1

Advertisement

Table of Contents
loading

Table of Contents