Humidity Sensing Fan Operation; Care And Maintenance - Utilitech 7131-03 Instructions Manual

Humidity sensing ventilation fan
Table of Contents

Advertisement

Available languages

Available languages

EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS
6.
Attach grille (B) by pinching mounting springs (6.1) and
inserting into narrow rectangular slots in fan housing (A).

HUMIDITY SENSING FAN OPERATION

1.
Humidity Sensing Mode: Flip the wall on/off switch to
the "ON" position. The LED indicator light in the fan is
BLUE. The fan will automatically run when the humidity
level in the room is above 60%. If the humidity level is
below 60%, the fan will stop automatically.
BLUE
LED
LIGHT
2.
Full Speed Mode: Cycle the wall on/off switch to the
"OFF" position, then back to the "ON" position. The
LED indicator light in the fan is AMBER. The fan will
run continuously, regardless of humidity level.
AMBER
LED
LIGHT
3.
Fan Off: Move wall on/off switch to "OFF" position.

CARE AND MAINTENANCE

WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding.
Routine maintenance should be done at least once a year.
• Wash grille with mild soap and water, dry with a cloth.
• Remove excess dirt and dust from the fan housing with a vacuum cleaner.
• Do not use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse resin parts in water over 140º F.
6
6.1
1
2
3
10
A
B

Advertisement

Table of Contents
loading

Table of Contents