2. Loosen the screws on the front cover of the Connection Unit using the supplied Allen key, as shown
below:
3. Remove the Connection Unit cover.
4. Open the required conduit drill guides according to the conduits used in the installation (refer to the
figure below for required drill guides; some of the drill guides may already be open but sealed): The
drill guides are located at the bottom and sides of the enclosure, each with two sizes: ¾'' and 1''. Open
the required drill guides, taking care not to interfere with any of the internal components. It is
recommended to use a U nibit drill.
NOTE
Unused conduit openings and glands should be sealed with appropriate seals.
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
Figure 45: Opening the Connection Unit cover
Figure 46: Connection Unit drill guides
Appendix B: Opening Conduit Drill Guides
103