Takex MW-100AL Instruction Manuals page 3

Microwave sensor

Advertisement

5
WIRING
Terminal arrangement
Power
(non-polarity)
Tamper output
Dry contact relay output N.C.
30V (AC/DC) 0.1A
Wiring
The equipment must be powered from an LPS in accordance with EN60950-1 : 2001
1) Basic connection
① ②
① ② ③ ④
RE
TR
4) Wiring distance
Size of wire used
AWG 20 (Dia. 0.8mm)
AWG 18 (Dia. 1.0mm)
AWG 17 (Dia. 1.1mm)
AWG 16 (Dia. 1.25mm)
AWG 15 (Dia. 1.4mm)
AWG 14 (Dia. 1.6mm)
6
SET-UP OF FUNCTIONS AND
BEAM ALIGNMENT
1) Supply power with covers off.
2) Look through the view nder on the transmitter unit and move it
until the receiver unit is visible.
Repeat the procedure on the receiver unit.
3) Set the adjustment mode switch on the receiver to "adjustment mode".
Connect the digital volt meter to the monitor jack and check the
monitor output voltage (beam reception level).
When the output voltage is low, adjust the installation height of the
transmitter and receiver so that the output voltage will reach the
highest level. (Make sure that the angle of the antenna does not
change.)
4) After adjustment, make sure that the adjustment switch is set to
"Operation mode".
Antenna
Digital voltmeter
After adjustment, set the adjustment mode switch to "Operation mode".
Install the sensor at a proper height and position otherwise
Note:
detection area could be widened over 6.6' (2m).
This could cause the sensor to detect movements of cars or
vegetations near the area and lead to frequent false alarms.
[Transmitter]
12 to 28V DC
2) When two or more sets are connected to
the same line.
Power
(DC12V)
Alarm
signal
(N.C.)
(Control panel)
①②
①②③④ ①②③④
TR
RE
Power voltage
12V DC
Up to
660ft. (200m)
Up to 1,000ft. (300m)
Up to 1,350ft. (400m)
Up to 1,800ft. (550m)
Up to 2,300ft. (700m)
Up to 2,950ft. (900m)
Vertical angle
adjustment screw
Adjustment dial
Voltage reading
2.1V or more
1.8V to 2.1V
1.8V or less
Poor, re-adjust
Alarm output
Dry contact relay Form C
30V (AC/DC) 0.25A
Tamper output
Dry contact relay output N.C.
30V (AC/DC) 0.1A
Power
(DC12V)
Alarm
signal
(N.C.)
(Control panel)
①②
RE
TR
24V DC
Up to 5,300ft. (1,600m)
Up to 7,800ft. (2,400m)
Up to 9,500ft. (2,900m)
Up to 12,500ft. (3,800m)
Up to 17,000ft. (5,100m)
Up to 21,000ft. (6,400m)
7
After the installation and angle adjustment are
test throug walk testing the sensor.
Two methods may be used.
Note:
1) Check by alarm LED only.
2) Check by both the alarm LED and control panel
Sensitivity
Best
Good
TR
[Receiver]
Power
12 to 28V DC
(non-polarity)
COM.
N.O.
N.C.
3) When two or more sets are connected
to separate lines.
①②
①②③④ ①②③④
RE
RE
TR
Note : 1)
Max. wiring distance, when two or
more sets are connected, is the above
value divided by the number of sets.
2)
The signal line can be wired to a
distance of up to 6,000ft. (2,000m)
with AWG 20 (dia.0.8mm) telephone
wire.
OPERATION CHECK
nished, test operation by performing a walking
When cover is attached, the sensor is switched
to be in an operation mode automatically.
Light
TR
Light
RE
Power
(DC12V)
Alarm signal
1(N.C.)
Alarm signal
2(N.C.)
(Control panel)
①②
TR
RE