TagMaster XT-2 Installation Manual & Data Sheet page 7

Table of Contents

Advertisement

XT-2 Reader Installation Manual & Data Sheet
The equipment must be disconnected from all voltage sources before any installation
or service work is carried out. Capacitors inside the equipment can hold their charge
even if the equipment has been disconnected from all voltage sources.
Caution!
Damage may be the result if the equipment is switched on when parts are removed
from the controller board, or if a PCB is removed within one minute after switching off
the equipment.
3.2.1
Tools
The following tools are necessary for installation:
Socket wrench
Hexagon socket 7 (for M4 casing nuts and XT-2 mounting kit)
Adjustable spanner
Screwdriver, Philips PH00x60 or SZS 0,4x2,5
Side cutter
Wire stripper
Crimping tool for ferrules
3.2.2
Cables and Power Supply
Cables and power supply are not supplied with the XT-2 reader.
All cables should be shielded and suitable for the installation environment, for instance
indoor or outdoor environment. Use flexible cables with stranded wire.
The terminal blocks used are Phoenix, type PT 1.5, which allow for a cable area of 0.2
to 1.5 mm² (AWG 26-14). Stranded wires must be fitted with a ferrule before being
inserted in the termination blocks.
The cable for the RS485 interface must be a twisted pair cable and conform to the EIA
RS485 standard.
A category 5 (CAT5e) cable is required for the Ethernet connection.
The reader shall be powered by a UL Listed or Certified, Class 2 or LPS power supply
suitable for outdoor use, rated 24 V DC, 1 A minimum. The power supply shall fulfil the
specifications in section 5.4.2, "Power supply, J31".
© TagMaster
Doc no. 10-407 02
7 (26)