Donaldson Torit Downflo Evolution DFEP4 Installation, Operation And Maintenance Manual

Donaldson Torit Downflo Evolution DFEP4 Installation, Operation And Maintenance Manual

Advertisement

safety related instructions and warnings in this manual. DO NOT operate or perform maintenance on this
collector until you have read and understood the instruction and warnings contained within this manual.
English
Master Language
DFEP4 and DFEP6
Installation, Operation and
Maintenance Manual
Evolution
®
. The hazard alert image denotes
IOM AK0303601 (ENG)
Revision 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Downflo Evolution DFEP4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Donaldson Torit Downflo Evolution DFEP4

  • Page 1 Evolution ® DFEP4 and DFEP6 Installation, Operation and Maintenance Manual . The hazard alert image denotes safety related instructions and warnings in this manual. DO NOT operate or perform maintenance on this collector until you have read and understood the instruction and warnings contained within this manual. IOM AK0303601 (ENG) English Master Language...
  • Page 2 For additional copies of this manual, contact Donaldson Torit. The Safety Alert Symbol indicates a hazardous situation which, if not avoided could result in death or serious injury. Obey all safety messages following this symbol to avoid possible injury or death.
  • Page 3: Table Of Contents

    Contents IMPORTANT NOTES ..................................i Safety Communication ................................1 Product Description ...................................2 Standard Equipment ................................3 Inlet ....................................3 Filters ..................................3 Delta P-C01control ..............................3 Dust Bin ..................................4 Fan and Motor ................................4 ..............................4 Compressed Air Connection ............................4 Sprinkler Tap ................................4 Collector Options ................................5 Top Mounted Junction Box ............................5 Delta P Plus Control ..............................5 Extended Capacity Dust Bin ............................5 Accessories ..................................5...
  • Page 4: Safety Communication

    Donaldson Company, Inc. Safety Communication Improper operation of dust collectors and/or dust control systems may contribute to conditions in a work area or facility which could result in severe personal injury, and product or property damage. All dust collection equipment should be used only for its intended purpose and should be properly selected and sized for its intended use.
  • Page 5: Product Description

    Product Description ® air stream. The standard collector comes equipped with an inlet near the top of the collector which allows an integrated fan to draw standard pulse cleaning controls can be upgraded to allow for ‘down-time’ collector is positioned and anchored in place. Plant power is wired to the top mounted junction box. Compressed air is supplied to collector is ready for operation.
  • Page 6: Standard Equipment

    Donaldson Company, Inc. Standard Equipment Inlet Filters are installed in the correct orientation and direction during servicing. Delta P-C01 Control The DFEP ships with a Delta P controller to monitor differential pressure between the clean-air and dirty-air plenums and provides The Delta P control and a pulse control timer manage pulse cleaning from user established High and Low Pressure Set Points.
  • Page 7: Dust Bin

    Dust Bin The standard dust bin is located below the hopper to collect dust removed from the air stream. The dust bin is sealed to the hopper discharge with a convenient clamping arrangement which lifts the dust bin against a sealing gasket on the base of the hopper to ensure a dust tight seal during operation.
  • Page 8: Collector Options

    The DFEP can be equipped with factory installed explosion relief panels to support a process owner's combustible dust mitigation strategy. Explosion vent sizing follows NFPA-68 formulas assuming outdoor location of the collector, with no duct or obstruction on the explosion vent panel(s). Contact Donaldson Torit for explosion venting requirements for other conditions. Remote Mounted Controls The DFEP controls can be provided external rather than internal to the collector if desired.
  • Page 9: Operation

    Operation During normal operation, dust-laden air is drawn into the collector through a duct connected to the inlet box, near the top of the collector. The dust-laden air is then directed downward through the collector body where heavier dust falls directly into the hopper. air passes into the clean-air plenum where it is drawn through the fan and is discharged through the clean-air outlet.
  • Page 10: Dfep Operation Checklist

    Donaldson Company, Inc. DFEP Operation Checklist more frequently if more than 2/3 full. • The DFEP collector can be interlocked to start and stop operation with associated fume producing equipment. Observe is shut down. • If the DFEP is operated independently from associated fume producing equipment the DFEP should be turned on before turning on any associated equipment, and shut off after the associated equipment is shut down.
  • Page 11: Product Service

    Product Service During any service activities there is some potential for exposure to the dust in the collector. Most dusts present safety and health hazards that require precautions. Wear eye, respiratory, head, and other protection equipment suitable for the type of dust when performing any service activities.. LOCK-OUT all energy sources prior to performing any service or maintenance on the equipment.
  • Page 12: Filter Replacement

    Donaldson Company, Inc. Filter Replacement Most dusts present safety and health hazards that require precautions. Wear eye, respiratory, head and other protection equipment suitable for the type of dust. damage. 1. Turn off collector and Lock-Out all energy sources. endcap (non-gasketed end) must match with the alignment mark ( 7.
  • Page 13 which can be monitored. 1. Turn off collector and Lock-Out all energy sources.
  • Page 14: Diaphragm Valve Repair

    Donaldson Company, Inc. Diaphragm Valve Repair A damaged diaphragm valve can be serviced, repaired or replaced. To repair or replace a damaged valve: may indicate a damaged cleaning valve). 2. Turn off the collector and Lock-Out all energy sources being certain to close the compressed air shut off valve (owner supplied) and bleed pressure from the DFEP manifold.
  • Page 15: Filter Access Cover Assembly Replacement

    Filter Access Cover Assembly Replacement 1. Turn off collector and Lock-Out all energy sources 4. Remove the Access Cover Pin, Clevis and E-Clip from the collector end of the access cover hinge assembly. the upper and lower Hinge Pin Shoulder Spacers. After the knob has been hand tightened (3-turns) a tool assist may be used.
  • Page 16: Yoke Replacement (Special Tool Required)

    Donaldson Company, Inc. Yoke Replacement (Special tool required) 1. Turn off the collector and Lock-Out all energy sources. 5. Open the control panel access door. Locate and remove the nuts, fender washers and star washers from the damaged yoke through the control panel access door.
  • Page 17: Fan And Motor Replacement

    Fan and Motor Replacement To replace a damaged fan or motor assembly: 1. Turn off the collector and Lock-Out all energy sources. 2. Open the dust bin access door. 3. Remove the dust bin. (If collector has an extended capacity dust bin, skip to Step 5.) 4.
  • Page 18 Donaldson Company, Inc. 16. Reinstall the lower hopper assembly for the dust bin. (If you have an extended capacity drum skip to step 17.) b. Position lower hopper assembly under hopper. d. Lift lower hopper assembly into position and tighten hardware. 17.
  • Page 19: Troubleshooting

    Troubleshooting Problem Probable Cause Remedy Not wired correctly Check supply voltage and wiring connections. Review Fan/blower does not motor manufacturer’s wiring diagram, collector wiring start schematics, and the National Electric Code and correct any wiring errors. Electrical circuit down Check power supply and correct any faults to restore power.
  • Page 20 Donaldson Company, Inc. Troubleshooting Problem Probable Cause Remedy Fan exhaust restricted Check fan exhaust area and remove any obstructions. continued Fan rotation backwards Check fan rotation when observed through control panel access opening. Reverse rotation if necessary. No power to the controller Use a voltmeter to check for supply voltage.
  • Page 21 Problem Probable Cause Remedy Pressure switch not wired to the Connect the pressure switch on the timer board to Pulse cleaning never timer board correctly Terminals 7 and 8 on TB3. stops Pressure switch terminals on the Remove jumper wire on Solid-State Timer board before timer board jumpered wiring to the Delta P Control.
  • Page 22: Appendix A - Collector Installation

    Donaldson Company, Inc. Appendix A - Collector Installation...
  • Page 23 Front View Front View Typical Side View DFEP 4 DFEP 6 Collectors are rated for the following loads as calculated per relevant sections of the IBC 2012 code*: Basic Wind Speed & Exposure ....90 mph, Exposure C Seismic Spectral Acceleration, S ........
  • Page 24: Collector Installation

    Claims Inspector to substantiate all damage claims. Compare the collector received with the description of product ordered. Report any incomplete shipments to the delivery carrier and your Donaldson Torit representative (DFEP Collectors are generally packaged and shipped laying on their side) Unloading and Positioning Failure to lift the collector correctly can result in severe personal injury and/or property damage.
  • Page 25: Provisional Anchor Bolt Recommendations

    Provisional Anchor Bolt Recommendations The quantity of anchor bolts should match the number of holes provided in the base plates of the collector. Anchor diameter is Anchor should project typically 1/8-inch less than the baseplate hole diameter. Anchors a minimum of 1 3/4-in should project a minimum of 1 ¾...
  • Page 26 Donaldson Company, Inc. Typical Lifting Methods shut-off valve with safety exhaust valve* automatic condensate valve* air supply line* air regulator* *to be supplied by owner Compressed Air and Component Installation...
  • Page 27: Initial Start-Up / Commissioning

    Initial Start-up / Commissioning Once the DFEP has been placed, anchored and connected to electrical power, compressed air and to a duct from the associated equipment, the collector is ready for initial start and commissioning. Typical commissioning sequence: 1. Once powered, verify the Delta P-C01 (or Delta P Plus) comes “on line” and shows a filter restriction of near zero on the digital display.
  • Page 28: Decommissioning Collector

    Donaldson Company, Inc. Decommissioning Collector Once the collector has reached the end of operational life it will need to be decommissioned. During decommissioning, there is potential for exposure to the dust in the collector. Most dusts present safety and health hazards that require precautions\. Wear eye, respiratory, head, and other protection equipment suitable for the type of dust when performing any decommissioning activities.
  • Page 29: Collector Information

    Collector Information (Process Owner to complete and retain for your records) Model Number _________________________________ Serial Number ___________________________________ Ship Date _____________________________________ Installation Date __________________________________ Filter Type_____________________________________________________________________________________ Dust Being Collected ____________________________________________________________________________ Dust Properties: Kst _______________Pmax ______________ MIE ____________ MEC __________________ Accessories ___________________________________________________________________________________ Other ________________________________________________________________________________________ _____________________________________________________________________________________________ Service Notes...
  • Page 30 Donaldson Company, Inc. Service Notes...
  • Page 31 The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions. Donaldson warrants all other Donaldson built components and accessories including Donaldson Airlocks, TBI Fans, TRB Fans, Fume Collector products and Donaldson built Afterfilters for twelve (12) months from date of shipment.

This manual is also suitable for: