Summary of Contents for Donaldson Torit Vibra-Shake VS-550
Page 1
Vibra-Shake ™ VS-550, VS-1200, VS-1500, VS-2400 and VS-3000 Installation and Operation Manual Installation, Operation, and Service Information VS-2400 VS-1200 This manual is property of the owner. Leave with the collector when set-up and start-up are complete. Donaldson Company reserves the right to change design and specifications without prior notice.
Page 2
Installation and Operations Manual. For a replacement manual, contact Donaldson Torit. This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures.
Consult and comply with all National and Local Codes related to fire and/or explosion properties of combustible materials when determining the location and operation of all dust, fume, or mist collection equipment. Standard Donaldson Torit equipment is not equipped with fire extinguishing or explosion protection systems.
Vibra-Shake, VS-550 to VS-3000 Operation Dust enters through the cabinet inlet and passes through 60-seconds after the fan is turned OFF for the VS-550, a fine mesh pre-filter on the outside of the filter. The VS-1200, and VS-1500 and 180-seconds for Models pre-filter is spaced 1-in from the filter cartridge and is VS-2400 and VS-3000.
Turn power off and lock out all power before 6. Report incomplete shipments to the delivery carrier performing service or maintenance work. and your Donaldson Torit representative. Do not install in classified hazardous 7. Remove crates and shipping straps. Remove loose...
Vibra-Shake, VS-550 to VS-3000 Rigging Instructions Collector Location Donaldson Torit equipment Suggested Tools & Equipment is not designed to support Clevis Pins and Clamps Lifting Slings site installed ducts, interconnecting piping, Crane or Forklift Pipe Sealant or electrical services. All ducts, piping,...
Donaldson Company, Inc. Standard Equipment Dust Drawer Collectors Standard equipment consists of a self-contained Reference Typical Foundation Anchor and leg assembly collector housing the filters, blower, clean- and dirty- drawing shipped with the collector prior to starting air chambers, and dust drawers. Locate the collector assembly.
Vibra-Shake, VS-550 to VS-3000 Provisional Anchor Bolt Recommendations 1. Consider Hilti HIT-HY 200 Anchor System or 6. Position and bolt the cross brace in place using the equivalent. Quantity of anchor bolts should match the hardware provided. Do not tighten hardware. number of holes provided in the base plates.
Donaldson Company, Inc. Cabinet Assembly 1. Place 1/4-in diameter, rope-type sealant around the 3. Align the holes in the hopper flange with the holes in hopper’s top flange toward the outside of the bolt the cabinet and secure using the hardware supplied. pattern.
Vibra-Shake, VS-550 to VS-3000 Electrical Wiring 2. Turn the fan motor ON then OFF to check for proper rotation by referencing the rotation arrow located on Electrical installation, service, the motor’s mounting plate. or maintenance work must be performed by a qualified electrician and To reverse rotation, three-phase power supply: comply with all applicable national and local Switch any two leads on the motor junction box.
Page 12
Donaldson Company, Inc. Disconnect Switch Motor Starter Enclosure Blower Motor 208/230/460/60/3 220/380/440/60/3 Control Enclosure Timer 115-V Board M2 M1 white Cleaning L2 L1 Switch 1/8 Hp 115-V 60 Hz Single Shaker Motor 1 Ph 1/8 Hp 115-V 60 Hz 1 Ph Double Shaker Motor Cleaning Operation Timer Connection...
Vibra-Shake, VS-550 to VS-3000 Preliminary Start-Up Check Instruct all personnel on safe use and maintenance 3. All access panels should be sealed and secure. procedures. 4. Check that the dust container is properly sealed and Electrical work during clamped. installation, service or 5.
Donaldson Company, Inc. Maintenance Information Filter Removal and Installation Instruct all personnel on safe use and maintenance Use proper safety and procedures. protective equipment when removing contaminants and filters. Use proper equipment and adopt all safety precautions Dirty filters may be heavier than they appear. needed for servicing equipment.
Vibra-Shake, VS-550 to VS-3000 Filter Installation Dust Disposal 1. Check the gasket surface on the shaker panel and To avoid possible damage to the clean as necessary. fan motor maintain a seal below the collector if servicing the dust storage 2.
Donaldson Company, Inc. Optional Equipment 55-Gallon Drum Pack The drum pack is designed to fit a customer-supplied, 4. Use latches to secure the cover to the drum, if standard 55-gallon drum and provides easy access for equipped. dust removal and disposal. A flexible hose connects 5.
Vibra-Shake, VS-550 to VS-3000 5-Gallon Pail Pack 1. Apply sealant to the hopper flange or the pail cover mounting plate flange toward the inside edge of the bolt pattern. 2. Fasten the pail pack to the hopper using the bolts, washers, and nuts supplied.
Donaldson Company, Inc. Control Box See Detail optional transformer timer control Note: F2 and F3 present on units with optional transformer only Control Box Assembly 180-sec wait 180-sec wait 30-sec clean 30-sec clean 60-sec time 60-sec time 90-sec 90-sec Single VS-550, 1200, and 1500 Double VS-2400 and 3000 Switches preset to OFF position.
Vibra-Shake, VS-550 to VS-3000 Shaker Assembly 1/8 hp TENV motor 115Volt, 50-60hz, 1ph nylon link bearing shaker bolt shaker bar jam nut eccentric: shaker bar must be at the lowest position of the shaft rotation to position the shaker ring. Adjust using jam nuts to .125 +- .005-in gap all around.
Electrical circuit overload Check that the power supply circuit has sufficient power to run all equipment. Inlet too large Contact Donaldson Torit for assistance. Filters not installed correctly See Filter Installation. Clean-air outlet discharging dust Filter damage, dents in the end Replace filters as necessary.
Page 21
Installation. Collapsed or obstructed Remove and clean duct. Replace collapsed duct. ductwork Improper duct size or too much Contact Donaldson Torit for assistance. flexible duct Collapsed or obstructed Remove and clean duct. Replace collapsed duct. ductwork Improper duct size or too much Contact Donaldson Torit for assistance.
Page 22
Donaldson Company, Inc. Troubleshooting Problem Probable Cause Remedy No input voltage to transformer Check and correct voltage at the transformer’s Control board indicator light not flashing primary and secondary terminal. See Electrical Connection. No output voltage from Replace transformer fuse with identical fuse only. transformer Other types may cause shaker motor damage.
Vibra-Shake, VS-550 to VS-3000 Collector Information (Process Owner to complete and retain for your records) Model Number _____________________________ Serial Number ______________________________ Ship Date _________________________________ Installation Date _____________________________ Filter Type ____________________________________________________________________________ Collected Dust ________________________________________________________________________ Dust Properties: Kst ______________Pmax _____________MIE ___________MEC ________________ Accessories __________________________________________________________________________ Other ________________________________________________________________________________ ____________________________________________________________________________________...
Page 24
The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions. Donaldson warrants all other Donaldson built components and accessories including Donaldson Airlocks, TBI Fans, TRB Fans, Fume Collector products and Donaldson built Afterfilters for twelve (12) months from date of shipment.
Need help?
Do you have a question about the Vibra-Shake VS-550 and is the answer not in the manual?
Questions and answers