Advertisement

This manual is property of the owner. Leave with the collector when set-up and start-up are complete. Donaldson Company reserves the
right to change design and specifications without prior notice.
Illustrations are for reference only as actual product may vary.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
English
Master Language
Vibra-Shake
VS-550, VS-1200, VS-1500, VS-2400 and VS-3000
Installation and Operation Manual
Installation, Operation, and Service Information
VS-1200
VS-2400
IOM 4077700 (ENG)
Revision 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vibra-Shake VS-550 and is the answer not in the manual?

Questions and answers

Summary of Contents for Donaldson Torit Vibra-Shake VS-550

  • Page 1 Vibra-Shake ™ VS-550, VS-1200, VS-1500, VS-2400 and VS-3000 Installation and Operation Manual Installation, Operation, and Service Information VS-2400 VS-1200 This manual is property of the owner. Leave with the collector when set-up and start-up are complete. Donaldson Company reserves the right to change design and specifications without prior notice.
  • Page 2 Installation and Operations Manual. For a replacement manual, contact Donaldson Torit. This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures.
  • Page 3: Table Of Contents

    Vibra-Shake, VS-550 to VS-3000 Contents Description ................1 Preliminary Start-Up Check ..........10 Purpose and Intended Use ............1 Maintenance Information .............11 Rating and Specification Information ........1 Operational Checklist ............11 Operation ...................2 Filter Removal and Installation .........11 Inspection on Arrival ...............3 Dust Disposal ..............12 Installation Codes and Procedures ........3 Optional Equipment..............13 Installation.................3...
  • Page 4: Description

    Consult and comply with all National and Local Codes related to fire and/or explosion properties of combustible materials when determining the location and operation of all dust, fume, or mist collection equipment. Standard Donaldson Torit equipment is not equipped with fire extinguishing or explosion protection systems.
  • Page 5: Operation

    Vibra-Shake, VS-550 to VS-3000 Operation Dust enters through the cabinet inlet and passes through 60-seconds after the fan is turned OFF for the VS-550, a fine mesh pre-filter on the outside of the filter. The VS-1200, and VS-1500 and 180-seconds for Models pre-filter is spaced 1-in from the filter cartridge and is VS-2400 and VS-3000.
  • Page 6: Inspection On Arrival

    Turn power off and lock out all power before 6. Report incomplete shipments to the delivery carrier performing service or maintenance work. and your Donaldson Torit representative. Do not install in classified hazardous 7. Remove crates and shipping straps. Remove loose...
  • Page 7: Collector Location

    Vibra-Shake, VS-550 to VS-3000 Rigging Instructions Collector Location Donaldson Torit equipment Suggested Tools & Equipment is not designed to support Clevis Pins and Clamps Lifting Slings site installed ducts, interconnecting piping, Crane or Forklift Pipe Sealant or electrical services. All ducts, piping,...
  • Page 8: Standard Equipment

    Donaldson Company, Inc. Standard Equipment Dust Drawer Collectors Standard equipment consists of a self-contained Reference Typical Foundation Anchor and leg assembly collector housing the filters, blower, clean- and dirty- drawing shipped with the collector prior to starting air chambers, and dust drawers. Locate the collector assembly.
  • Page 9: Provisional Anchor Bolt Recommendations

    Vibra-Shake, VS-550 to VS-3000 Provisional Anchor Bolt Recommendations 1. Consider Hilti HIT-HY 200 Anchor System or 6. Position and bolt the cross brace in place using the equivalent. Quantity of anchor bolts should match the hardware provided. Do not tighten hardware. number of holes provided in the base plates.
  • Page 10: Cabinet Assembly

    Donaldson Company, Inc. Cabinet Assembly 1. Place 1/4-in diameter, rope-type sealant around the 3. Align the holes in the hopper flange with the holes in hopper’s top flange toward the outside of the bolt the cabinet and secure using the hardware supplied. pattern.
  • Page 11: Electrical Wiring

    Vibra-Shake, VS-550 to VS-3000 Electrical Wiring 2. Turn the fan motor ON then OFF to check for proper rotation by referencing the rotation arrow located on Electrical installation, service, the motor’s mounting plate. or maintenance work must be performed by a qualified electrician and To reverse rotation, three-phase power supply: comply with all applicable national and local Switch any two leads on the motor junction box.
  • Page 12 Donaldson Company, Inc. Disconnect Switch Motor Starter Enclosure Blower Motor 208/230/460/60/3 220/380/440/60/3 Control Enclosure Timer 115-V Board M2 M1 white Cleaning L2 L1 Switch 1/8 Hp 115-V 60 Hz Single Shaker Motor 1 Ph 1/8 Hp 115-V 60 Hz 1 Ph Double Shaker Motor Cleaning Operation Timer Connection...
  • Page 13: Preliminary Start-Up Check

    Vibra-Shake, VS-550 to VS-3000 Preliminary Start-Up Check Instruct all personnel on safe use and maintenance 3. All access panels should be sealed and secure. procedures. 4. Check that the dust container is properly sealed and Electrical work during clamped. installation, service or 5.
  • Page 14: Maintenance Information

    Donaldson Company, Inc. Maintenance Information Filter Removal and Installation Instruct all personnel on safe use and maintenance Use proper safety and procedures. protective equipment when removing contaminants and filters. Use proper equipment and adopt all safety precautions Dirty filters may be heavier than they appear. needed for servicing equipment.
  • Page 15: Dust Disposal

    Vibra-Shake, VS-550 to VS-3000 Filter Installation Dust Disposal 1. Check the gasket surface on the shaker panel and To avoid possible damage to the clean as necessary. fan motor maintain a seal below the collector if servicing the dust storage 2.
  • Page 16: Optional Equipment

    Donaldson Company, Inc. Optional Equipment 55-Gallon Drum Pack The drum pack is designed to fit a customer-supplied, 4. Use latches to secure the cover to the drum, if standard 55-gallon drum and provides easy access for equipped. dust removal and disposal. A flexible hose connects 5.
  • Page 17: 5-Gallon Pail Pack

    Vibra-Shake, VS-550 to VS-3000 5-Gallon Pail Pack 1. Apply sealant to the hopper flange or the pail cover mounting plate flange toward the inside edge of the bolt pattern. 2. Fasten the pail pack to the hopper using the bolts, washers, and nuts supplied.
  • Page 18: Control Box

    Donaldson Company, Inc. Control Box See Detail optional transformer timer control Note: F2 and F3 present on units with optional transformer only Control Box Assembly 180-sec wait 180-sec wait 30-sec clean 30-sec clean 60-sec time 60-sec time 90-sec 90-sec Single VS-550, 1200, and 1500 Double VS-2400 and 3000 Switches preset to OFF position.
  • Page 19: Shaker Assembly

    Vibra-Shake, VS-550 to VS-3000 Shaker Assembly 1/8 hp TENV motor 115Volt, 50-60hz, 1ph nylon link bearing shaker bolt shaker bar jam nut eccentric: shaker bar must be at the lowest position of the shaft rotation to position the shaker ring. Adjust using jam nuts to .125 +- .005-in gap all around.
  • Page 20: Troubleshooting

    Electrical circuit overload Check that the power supply circuit has sufficient power to run all equipment. Inlet too large Contact Donaldson Torit for assistance. Filters not installed correctly See Filter Installation. Clean-air outlet discharging dust Filter damage, dents in the end Replace filters as necessary.
  • Page 21 Installation. Collapsed or obstructed Remove and clean duct. Replace collapsed duct. ductwork Improper duct size or too much Contact Donaldson Torit for assistance. flexible duct Collapsed or obstructed Remove and clean duct. Replace collapsed duct. ductwork Improper duct size or too much Contact Donaldson Torit for assistance.
  • Page 22 Donaldson Company, Inc. Troubleshooting Problem Probable Cause Remedy No input voltage to transformer Check and correct voltage at the transformer’s Control board indicator light not flashing primary and secondary terminal. See Electrical Connection. No output voltage from Replace transformer fuse with identical fuse only. transformer Other types may cause shaker motor damage.
  • Page 23: Collector Information

    Vibra-Shake, VS-550 to VS-3000 Collector Information (Process Owner to complete and retain for your records) Model Number _____________________________ Serial Number ______________________________ Ship Date _________________________________ Installation Date _____________________________ Filter Type ____________________________________________________________________________ Collected Dust ________________________________________________________________________ Dust Properties: Kst ______________Pmax _____________MIE ___________MEC ________________ Accessories __________________________________________________________________________ Other ________________________________________________________________________________ ____________________________________________________________________________________...
  • Page 24 The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions. Donaldson warrants all other Donaldson built components and accessories including Donaldson Airlocks, TBI Fans, TRB Fans, Fume Collector products and Donaldson built Afterfilters for twelve (12) months from date of shipment.

Table of Contents