Technical Specifications - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Accessories
8.1 Wide-range power supply unit for SIMATIC RF systems
8.1.6

Technical specifications

Table 8-1
Insulation stability (prim./sec.) U
Insulation resistance R
Leakage current I
Safety class (SELV)
Mains buffering t
Ambient temperature
Surface temperature
Storage temperature
Self-heating on full-load
Interference immunity
ESD
HF fields
Burst
Surge
HF injection
Mains quality test
Cooling
Dimensions L x W x H
Weight
Housing / casting
Power supply class
Table 8-2
Rated input voltage U
Input voltage range U
Input frequency f
Radio interference level
Switching frequency f
Length of cable
8-6
General technical specifications
ins p/s
ins
leak
h
Technical specifications for the input
in
in
in
sw
U
= 230 V
, f = 50 Hz
in
AC
Designed for installation in devices of Safety Class 2
U
= 230 V
in
AC
Module top, centrally
EN 61000-4-2,
4-3 up to 4-6, 4-11
according to CSA
EN 60950 / UL 60950
System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
3.3 kV
AC
>1 GΩ
< 200 µA
≥50 ms
-25 °C to +55 °C
max. 96 °C
-40 °C to +85 °C
max. 45 K
Air discharge: 15 kV
10 V/m
symmetrical: 2
Symmetrical: 1
10 V
rms
Free convection
tbd x 85.0 x 35.0 mm
720 g
UL 94-V0
Level 3
100 to 240 V AC
120 to 353 V
DC
94 to 264 V AC
120 to 375 V
DC
(UL: 353 V
)
DC
50/60 Hz
EN 55011/B
approx. 70 kHz typ.
2 m
RF600

Advertisement

Table of Contents
loading

Table of Contents