Test Mode
Enter
This function performs a number of tests which are listed below. The next test is selected by
pressing any numeric key.
Test
1)
All LEDs are switched on except the fault LED.
2)
The strobe is switched on.
3)
The bell is switched on.
4)
The internal sounder is switched on.
To exit test mode press the
key again.
Walk Test Mode
Enter
followed by
-
-
or
.
When the walk test mode is enabled the 'chime' LED will flash. If the panel is then set each
active zone will cause a chime when triggered. This enables all the zone configurations to be
walk tested individually. The walk test mode is cleared when the panel is unset.
The numbers of any activated zones will be entered into the event log. Zones programmed
as Keyswitch zones when activated in walk test will not be entered in the event log.
Changing Master and Limited User Codes
Master Code
Enter
followed by
Enter
Enter the new code twice, three tones will be heard on acceptance of each command, a
single low tone indicates programming not accepted.
Master code cannot be deleted.
Limited User Code
Enter
followed by
Enter
to
Enter the new code twice, three tones will be heard on acceptance of each command, a
single low tone indicates programming not accepted.
To delete a user code press the
6
the master code and the set option, either
Master User Code (factory set at 1 2 3 4)
Master User Code (factory set at 1 2 3 4)
key after
to
is entered.

MASTER AND LIMITED USER FUNCTIONS

Setting the Panel
Enter
Refer to the Zone Programming Status Label to see how each set was configured by the
installation engineer.
Setting the Panel when the Mains Fails
Under normal operation the panel will indicate a fault condition if the AC supply is
disconnected. It will still be possible to Set and Unset the panel during a mains fail only if
allowed by the engineer, and no further action is required. Full functionality of the panel is
available during a mains failure.
Silent Setting of the Panel
Enter
and then
A dual tone will be heard on acceptance of the command, and another dual tone will be heard
when the panel is set.
Push to Set
Set the panel in any of the above methods. The panel will count down, but will not set until the
PTS button is pressed.
Final Door Set
Set the panel in any of the above methods, the panel will count down but will not set until the
final exit door is opened then closed.
Arm with Omits
If any zones are triggered whilst in ext mode a low pitched error tone will be heard, any faulty
zones will be displayed in the seven segment display. First check for any obvious reason for
these zones to have been activated.
This may simply be due to a monitored door or window being left open or a pet being left in a
protected area. If the fault cannot be rectified it is possible to omit faulty zones but this should
only be used as a last resort if the building is to be left unoccupied.
Example: Set panel,
RINS137-7
RINS137-7
(User Code)
and then
or
for set required.
then:
If no error tone heard, exit via normal route.
or:
If error tone heard:
Enter:
then;
number(s) of zones to be omitted (1 to 8)
then:
Entry / Exit timer will start again.
then:
exit building by normal route.
or
for set required.