H3C WA2620X-AGNP Installation Manual
Hide thumbs Also See for WA2620X-AGNP:
Table of Contents

Advertisement

Quick Links

H3C WA2620X-AGNP Access Point

Installation Guide

Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Document version: APW100-20110330

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for H3C WA2620X-AGNP

  • Page 1: Installation Guide

    H3C WA2620X-AGNP Access Point Installation Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document version: APW100-20110330...
  • Page 2 SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V G, V G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice.
  • Page 3 Preface The H3C WA2620X-AGNP AP Installation Guide describes the hardware specifications of the new generation WA2600 802.11n outdoor AP, preparations before installation, installation procedure, cabling and grounding, and login procedure. An appendix is included to describe how to crimp RJ-45 connectors.
  • Page 4: Obtaining Documentation

    Obtaining documentation You can access the most up-to-date H3C product documentation on the World Wide Web at http://www.h3c.com. Click the links on the top navigation bar to obtain different categories of product documentation: [Technical Support & Documents > Technical Documents] –...
  • Page 5: Table Of Contents

    Contents Product overview ······················································································································································································· 1   Overview ·········································································································································································································· 1   Hardware specifications ············································································································································································· 1   LEDs ········································································································································································································· 2   Ports ········································································································································································································· 3   Preparing for installation ········································································································································································ 6   Preparing installation tools ······································································································································································ 6   Examining the installation site ································································································································································ 6  ...
  • Page 6: Product Overview

    Product overview Overview H3C WA2620X-AGNP access point (AP) is a new-generation AP that supports 802.11n and can work in fit or fat mode. A fit AP can work with an access controller (AC) or wireless switch to provide WLAN access. A fat AP can provide WLAN access alone.
  • Page 7: Leds

    LEDs Figure 2 WA2620X-AGNP LEDs Table 2 LED description Color Quantity Description Indicates power status: POWER  On: The AP is powered on. Green (Power LED)  Off: The AP is powered off or operates abnormally. Indicates Ethernet port status: ...
  • Page 8: Ports

     Fast blinking: Data is being transmitted or received. Ports The WA2620X-AGNP AP provides three 2.4 GHz antenna ports and three 5.0 GHz antenna ports, a console port, Ethernet ports (fiber and copper), a power port, and a grounding terminal.
  • Page 9 Figure 3 WA2620X-AGNP port layout 1: 2.4G-1 antenna port 2: 2.4G-2 antenna port 3: 2.4G-3 antenna port 4: 5G-1 antenna port 5: 5G-2 antenna port 6: 5G-3 antenna port 7: ETH2 (1000BASE-FX fiber port) 8: ETH 1 (10/100/1000BASE-TX copper port)
  • Page 10 Standards and Port Function protocols IEEE802.3 ETH 1 Connects to the Internet or MAN and serves as a PoE IEEE802.3u 10/100/1000BASE-TX port. copper port IEEE802.3at 2.4G-1/2/3 IEEE802.11b/g/n Antenna port for 2.4 GHz band 5G-1/2/3 IEEE802.11a/n Antenna port for 5 GHz band CONSOLE RS/EIA-232 Console port for configuration and management...
  • Page 11: Preparing For Installation

    Preparing for installation This chapter describes how to prepare for the installation of the AP, including the preparation of tools and installation site survey. Preparing installation tools When installing the AP, you may need the tools listed in Table 4. Choose the appropriate tools according to the installation environment.
  • Page 12: Power Supply

    The AP can be powered by a power injector or through PoE+. Power injector You can use an H3C POE-5 power injector to power the AP. For more information about how to power the AP through the power injector, see “Connecting the AP to a power...
  • Page 13: Examining The Ap

    Item Requirements (0.05 in. ), or weld them directly. Use anti-erosion treatment on the welding joint.  Use a power cord with a protective earth (PE). Do not use a power cord with only an L line and an N line. Power grounding (AC) ...
  • Page 14: Installing The Ap

    Installing the AP The WA2620X-AGNP AP can be mounted on a pole. To ensure the radio coverage, have the AP installed by professionals. The installation involves the following procedures: Installing the AP Installing the outdoor antennas Connecting cables Verifying the installation...
  • Page 15 Figure 5 Adjust the tilt of the AP 1: Mounting plate 2: Bolt 3: Mounting slot (allows bracket rotation) 4: V-shaped bracket Pole mounting is suitable for rooftop installation. Follow these steps to install the AP on a pole: Vertically fix the pedestal of the pole to the rooftop or a cement pier on the rooftop with expansion Step1 screws, as shown in Figure...
  • Page 16 Figure 7 Mount the AP on the pole (vertical) 1: AP 2: Screw (M6 x 12) 3: Mounting plate 4: V-shaped bracket 5: Long bolt 6: #10 flat washer 7: #10 spring washer 8: M10 nut...
  • Page 17: Installing The Outdoor Antennas

    Figure 8 Mount the AP on the pole (horizontal) 1: AP 2: Mounting plate 3: V-shaped bracket 4: Long bolt 5: M10 nut 6: #10 spring washer 7: #10 flat washer 8: Screw (M6 x 12) Fix the AP onto the mounting plate with screws and fasten the screws, as shown in Figure 7 Step4 Figure...
  • Page 18: Installing A Directional Antenna On A Pole

    Installing a directional antenna on a pole NOTE: Ensure that the location of the pole does not hamper the adjustment of antenna direction and tilt. Before you install a directional antenna on the pole, make sure that the pole is vertical to the rooftop surface.
  • Page 19 Figure 10 Install a directional antenna on a parapet (II) Lightning rod Pole mounting bracket Directional outdoor antenna Pole 0.5 m 1.0 m Parapet Flat steel bar To the grounding grid If there is no parapet on the rooftop, fix the pole to the rooftop surface or a cement pier on ...
  • Page 20: Connecting Cables

    Wrap the connections with insulating tape and apply several layers of waterproof sealing tape over Step2 the insulating tape. NOTE: No antenna arrestor is needed. The WA2620X-AGNP AP provides lightning arresting  function. Make sure that the grounding cables are well grounded during outdoor deployment.
  • Page 21 CAUTION: Observe the following procedure when connecting the copper cable. Otherwise, the AP might be damaged. Route the Ethernet cable with waterproof sheath from the equipment room to the AP. Step1 Figure 12 Connect a copper cable Figure 13 Connect a fiber cable...
  • Page 22 Figure 14 Power injector NOTE: If the AP is powered by a PoE+ switch, no power injector is needed. Make sure that the  PoE+ switch can support the maximum power consumption of the AP. If a fiber cable is used to transmit data, the copper cable only provides power and does ...
  • Page 23: Connecting The Fiber Cable

    When a fiber cable is used to transmit data, both ends of the cable must use appropriate  SFP transceiver modules. The SFP transceiver modules provided by H3C meet the outdoor deployment requirements, use single mode fiber, and have a transmission distance of 15 km (9.32 mi).
  • Page 24: Connecting The Ap To The Power Source

    Connecting the AP to the power source The WA2620X-AGNP AP can be powered by a power injector or a PoE+ switch. Connecting the AP to a power injector...
  • Page 25: Connecting The Grounding Cable

    Connecting the grounding cable Connect the grounding terminal of the AP to the grounding point with the yellow and green grounding cable shipped with the AP, as shown in Figure 3. For more information about the procedure, see “Grounding and lightning protection”.
  • Page 26: Logging In To The Ap

    Logging in to the AP NOTE: A fit AP is zero-configuration and is managed by an access controller or wireless switch. This chapter describes how to log in to a fat AP on a web interface. Use the following factory default settings to log in to a fat AP on a web interface: Username: admin ...
  • Page 27: Appendix A Crimping An Rj-45 Connector

    Appendix A Crimping an RJ-45 connector You must insert the Ethernet cable through the liquid tight adapter before crimping an RJ-45 connector on the end of the cable (usually category 5 or category 5E cable). Figure 18 RJ-45 connector The following describes two common types of cables and how to make them. Straight-through cable: The colored wires are of the same sequence at the two ends of the ...
  • Page 28 Table 8 Crossover cable pin-outs RJ45 pin Signal Wire Signal direction RJ45 pin White-orange  Orange  White-green  Blue White-blue Green  White-brown Brown NOTE: The Ethernet ports of the AP are autosensing and can recognize both types of cables. ...
  • Page 29 Compliance and Safety Manual...
  • Page 30 Contents Safety Information Sicherheits informationen 安全信息   Conventions Used Symbole Erläuterung 应用惯例   Important Safety Information/Wichtige Sicherheitshinweise/重要安 全信息   Electricity Safety Elektrische Sicherheit 用电安全   Regulatory Compliance Information   Regulatory compliance standards (标题 2)   Support Antennas & Accessories information  ...
  • Page 31 List of Tables Table 1 Safety symbol and description ............1   Table 2 Regulatory compliance standards ............5   Table 3 Authorized Antennas & Accessories ..........6   Table 4 Equipment may be operated in the following country: .... 6   Table 5 R&TTE declaration statements: ............
  • Page 32: Safety Information Sicherheits Informationen 安全信息

    Safety Information Sicherheits informationen 安全信息 Conventions Used Symbole Erläuterung 应用 惯例 The symbols in this manual are shown in the following table. They are used to remind the reader of the safety precautions during equipment installation and maintenance. Die Symbole in diesem Handbuch verwendeten sind in der folgenden Tabelle dargestellt.
  • Page 33: Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息

    Safety Description Symbol Erläuterung Symbole 描述 安全标识 Elektrischer Schlag: Hinweis auf Gefährdung durch Hochspannung 电击防护标识:用于表示高压危险 Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息 Caution: You must read all of the installation instructions in the Installation Guide supplied with your equipment and the following safety instructions before installation or operation. Achtung: Sie müssen vor der Installation oder Bedienung das mit Ihrer Anlage mitgelieferten Installationshandbuch und die folgende Sicherheitshinweise lesen.
  • Page 34: Electricity Safety Elektrische Sicherheit 用电安全

    actual installation. Warnung: Überprüfen Sie vor dem Anbringen der Zuleitung immer, ob das von Ihnen verwendete Kabel den Anforderungen entspricht. 警告:在进行线缆连接前,请确认线缆和线缆的标识与实际安装要求是一 致的。 WARNING: The unit must be permanently connected to the protective ground before operation. The cross-sectional area of the protective earthing / grounding conductor shall be at least 0.75 mm Warnung: Diese Anlage muss vor der Inbetriebnahme ständig an die Schutzleiter angeschlossen werden.
  • Page 35 Sollte sich Wasser im Baugruppenträger befinden oder der  Baugruppenträger feucht sein, ist die Energiezufuhr sofort zu unterbrechen und das System abzuschalten.  当有液体进入机架或机架有损坏时,请立即切断电源。 When operation is performed in a damp environment, make sure that  water is kept off the equipment. Muss in einem feuchten Umgebung gearbeitet werden, ist ...
  • Page 36: Regulatory Compliance Information

    Regulatory Compliance Information Regulatory compliance standards Table 2 Regulatory compliance standards Discipline Standards FCC Part 15 (CFR 47) Subpart B section 15.107&15.109 Class B ICES-003 Class B EN 61000-3-2 EN 61000-3-3 EN55024 EN55022 EN 301 489-1 EN 301 489-17 UL 60950-1 CAN/CSA C22.2 No 60950-1 Safety IEC 60950-1...
  • Page 37: Support Antennas & Accessories Information

    Support Antennas & Accessories information This product can be used with the following antennas and accessories: Table 3 Authorized Antennas & Accessories Item Description Exclusions Supplied Antenna None HP 2.4GHz 12dBi MIMO 3-element JG291A None Outdoor/Indoor Panel Antenna HP 5GHz 11dBi MIMO 3-element JG292A None Outdoor/Indoor Panel Antenna...
  • Page 38: Table 5 R&Tte Declaration Statements

    Select the country in which the product is installed to ensure product operation is in compliance with local regulations. For more information about how to select the country, see command about country-code in "WLAN Command Reference". Intended use: IEEE 802.11 a/b/g/n radio LAN device. This product must maintain a minimum body to antenna distance of 20cm.Under these conditions this product will meet the Basic Restriction limits of 1999/519/EC(Council Recommendation of 12 July...
  • Page 39 [French] pertinentes de la directive 1999/5/CE. Con la presente HP Corporation dichiara che questo RLAN è Italiano conforme ai requisiti essenziali ed alle altre disposizioni [Italian] pertinenti stabilite dalla direttiva 1999/5/CE. Ar šo HP Corporation deklarē, ka RLAN atbilst Direktīvas Latviski 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem [Latvian]...
  • Page 40: Eu Country Restriction In 2.4Ghz Band

    Hér með lýsir HP Corporation yfir því að RLAN er í samræmi við Íslenska grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun [Icelandic] 1999/5/EC. HP Corporation erklærer herved at utstyret RLAN er i samsvar Norsk med de grunnleggende krav og øvrige relevante krav i direktiv [Norwegian] 1999/5/EF.
  • Page 41: Eu Country Restriction In 5Ghz Band

    EU Country Restriction in 5GHz band In Italy the end-user must apply for a license from the national spectrum authority to operate this device outdoors. To remain in conformance with European spectrum usage laws for Wireless LAN operation, the above 2.4GHz and 5GHz channel limitations apply.
  • Page 42: Weee Directive-2002/96/Ec

    WEEE Directive–2002/96/EC The products this manual refers to are covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner. USA regulatory compliance FCC Part 15 US Federal Communications Commission (FCC) EMC Compliance The product complies with Part 15 of the FCC Rules.
  • Page 43 Increase the separation between the equipment and the receiver.  Connect the equipment into an outlet on a circuit different from that  to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.  Note: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate...
  • Page 44: Canada Regulatory Compliance

    Canada regulatory compliance ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. RF Compliance This device complies with Industry Canada licence-exempt RSS standard(s). Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
  • Page 45: Brazil Rf Compliance

    Pour empecher que cet appareil cause du brouillage au service faisant l'objet d'une licence, il doit etre utilize a l'interieur et devrait etre place loin des fenetres afin de Fournier un ecram de blindage maximal. Si le matriel (ou son antenne d'emission) est installe a l'exterieur, il doit faire l'objet d'une licence.
  • Page 46 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅 自變更頻率、加大功率或變更原設計之特性及功能。 射頻電信終端設備之使用不得影響飛航安全及干擾合法通信;經發現有干擾現 象時,應立即停用,並改善至無干擾時方得繼續使用。所謂合法通信,係指依 電信法規定作業之無線電信。低功率射頻電機須忍受合法通信或工業、科學及 醫療用電波輻射性電機設備之干擾。 輸入、製造射頻電信終端設備之公司、商號或其使用者違反本辦法規定,擅自 使用或變更無線電頻率、電功率者,除依電信法規定處罰外,電信總局並得撤 銷其審驗合格證明。 本機限在不干擾合法電台與不受被干擾保障條件下於室內使用。 在 5.25-5.35 秭赫頻帶內操作之無線資訊傳輸設備,限於室內使用。 無線資訊傳輸設備的製造廠商應確保頻率穩定性,如依製造廠商使用手冊上所 述正常操作,發射的信號應維持於操作頻帶中。 為減少電磁波干擾,請妥適使用。...